Qcells (Hanwha) Q.PEAK DUO-G6P+ 345
345 W, 120 half-cut cell monocrystalline module, white backsheet, 1000V or 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
345W / 320.8W
Efficiency
19.94%
Voc / Vmp
40.49V / 33.76V
Max String (600V)
13 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Qcells (Hanwha) |
|---|---|
| Model Number (MPN) | Q.PEAK DUO-G6P+ 345 |
| Cell Technology | Mono-c-Si · 120 cells |
| Nameplate Power (Pmax STC) | 345 W |
| Real-World Output (PTC) | 320.8 W (93% of STC) |
| Module Efficiency | 19.94% (199.4 W/m²) |
| Open-Circuit Voltage (Voc) | 40.49 V |
| Maximum Power Voltage (Vmp) | 33.76 V |
| Short-Circuit Current (Isc) | 10.73 A (NEC 1.25× = 13.41 A) |
| Maximum Power Current (Imp) | 10.22 A |
| Temp. Coeff. Power (γPmax) | -0.36 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.276 %/°C |
| Temp. Coeff. Current (αIsc) | +0.047 %/°C |
| Nominal Cell Temp (NOCT) | 45.1 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 1.73 m² (18.6 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.276%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 40.49 V | 14 | 24 |
| 0°C / 32°F Freezing / Mild Winter | 43.28 V | 13 | 23 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 44.4 V | 13 | 22 |
| -20°C / -4°F Northeast / Midwest Winter | 45.52 V | 13 | 21 |
| -30°C / -22°F Northern Plains / Mountain | 46.64 V | 12 | 21 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 18 panels | 6.21 kW | 335 sq ft (31.1 m²) |
| 8 kW | 24 panels | 8.28 kW | 447 sq ft (41.5 m²) |
| 10 kW | 29 panels | 10.01 kW | 540 sq ft (50.2 m²) |
| 12 kW | 35 panels | 12.07 kW | 652 sq ft (60.5 m²) |
Compatible CEC-Listed Inverters for Q.PEAK DUO-G6P+ 345
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–13 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 8–10 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ6PLUS-ACB-LL | Microinverter | 0.27 kW | 95.5% | 1:1 micro pairing (1.28 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 4–18 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 6–11 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-MS-US30 | String | 4.968 kW | 96.5% | 6–11 panels/string at -10°C | Verify Pair |
Other Power Classes in This Qcells (Hanwha) Series (4 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| Q.PEAK DUO-G6P+ 350 | 350 W | 325.6 W | 40.73 V | 10.79 A | 20.23% |
| Q.PEAK DUO-G6P+ 355 | 355 W | 330.4 W | 40.98 V | 10.84 A | 20.52% |
| Q.PEAK DUO-G6P+ 360 | 360 W | 335.2 W | 41.23 V | 10.9 A | 20.81% |
Engineering FAQ — Qcells (Hanwha) Q.PEAK DUO-G6P+ 345
How many Qcells (Hanwha) Q.PEAK DUO-G6P+ 345 panels can fit in one 600V string?
At -10°C (14°F) ambient, the Q.PEAK DUO-G6P+ 345 open-circuit voltage rises from 40.49V to 44.4V (using βVoc -0.276%/°C), allowing up to 13 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Qcells (Hanwha) Q.PEAK DUO-G6P+ 345?
Rated at 345W STC, the Q.PEAK DUO-G6P+ 345 carries a 320.8W PTC rating (93% PTC/STC ratio) and 19.94% module efficiency across 1.73 m² (18.6 sq ft).
Is the Qcells (Hanwha) Q.PEAK DUO-G6P+ 345 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.