Qcells (Hanwha) Q.PEAK DUO L-G6.3 425
425 W, 144 half cell monocrystalline module, white backsheet, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
425W / 393.7W
Efficiency
20.33%
Voc / Vmp
49.13V / 41.2V
Max String (600V)
11 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Qcells (Hanwha) |
|---|---|
| Model Number (MPN) | Q.PEAK DUO L-G6.3 425 |
| Cell Technology | Mono-c-Si · 144 cells |
| Nameplate Power (Pmax STC) | 425 W |
| Real-World Output (PTC) | 393.7 W (92.6% of STC) |
| Module Efficiency | 20.33% (203.3 W/m²) |
| Open-Circuit Voltage (Voc) | 49.13 V |
| Maximum Power Voltage (Vmp) | 41.2 V |
| Short-Circuit Current (Isc) | 10.83 A (NEC 1.25× = 13.54 A) |
| Maximum Power Current (Imp) | 10.32 A |
| Temp. Coeff. Power (γPmax) | -0.359 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.265 %/°C |
| Temp. Coeff. Current (αIsc) | +0.043 %/°C |
| Nominal Cell Temp (NOCT) | 46.4 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.09 m² (22.5 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.265%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 49.13 V | 12 | 20 |
| 0°C / 32°F Freezing / Mild Winter | 52.38 V | 11 | 19 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 53.69 V | 11 | 18 |
| -20°C / -4°F Northeast / Midwest Winter | 54.99 V | 10 | 18 |
| -30°C / -22°F Northern Plains / Mountain | 56.29 V | 10 | 17 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 15 panels | 6.38 kW | 337 sq ft (31.3 m²) |
| 8 kW | 19 panels | 8.07 kW | 427 sq ft (39.7 m²) |
| 10 kW | 24 panels | 10.20 kW | 540 sq ft (50.2 m²) |
| 12 kW | 29 panels | 12.32 kW | 652 sq ft (60.6 m²) |
Compatible CEC-Listed Inverters for Q.PEAK DUO L-G6.3 425
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–11 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 6–8 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ7X-96-2-US | Microinverter | 0.315 kW | 97% | 1:1 micro pairing (1.35 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 3–14 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 5–9 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-MS-US30 | String | 4.968 kW | 96.5% | 5–9 panels/string at -10°C | Verify Pair |
Other Power Classes in This Qcells (Hanwha) Series (3 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| Q.PEAK DUO L-G6.3 430 | 430 W | 398.4 W | 49.62 V | 10.92 A | 20.57% |
| Q.PEAK DUO L-G6.3 435 | 435 W | 403.2 W | 49.87 V | 10.97 A | 20.81% |
Engineering FAQ — Qcells (Hanwha) Q.PEAK DUO L-G6.3 425
How many Qcells (Hanwha) Q.PEAK DUO L-G6.3 425 panels can fit in one 600V string?
At -10°C (14°F) ambient, the Q.PEAK DUO L-G6.3 425 open-circuit voltage rises from 49.13V to 53.69V (using βVoc -0.265%/°C), allowing up to 11 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Qcells (Hanwha) Q.PEAK DUO L-G6.3 425?
Rated at 425W STC, the Q.PEAK DUO L-G6.3 425 carries a 393.7W PTC rating (92.6% PTC/STC ratio) and 20.33% module efficiency across 2.09 m² (22.5 sq ft).
Is the Qcells (Hanwha) Q.PEAK DUO L-G6.3 425 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.