400 W, 144 half-cut cell monocrystalline module, bifacial, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
400W / 373.2W
Efficiency
19.27%
Voc / Vmp
47.89V / 39.63V
Max String (600V)
11 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Qcells (Hanwha) |
|---|---|
| Model Number (MPN) | Q.PEAK DUO L-G6.3/BGT 400 |
| Cell Technology | Mono-c-Si (Bifacial) · 144 cells |
| Nameplate Power (Pmax STC) | 400 W |
| Real-World Output (PTC) | 373.2 W (93.3% of STC) |
| Module Efficiency | 19.27% (192.7 W/m²) |
| Open-Circuit Voltage (Voc) | 47.89 V |
| Maximum Power Voltage (Vmp) | 39.63 V |
| Short-Circuit Current (Isc) | 10.6 A (NEC 1.25× = 13.25 A) |
| Maximum Power Current (Imp) | 10.09 A |
| Temp. Coeff. Power (γPmax) | -0.334 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.263 %/°C |
| Temp. Coeff. Current (αIsc) | +0.041 %/°C |
| Nominal Cell Temp (NOCT) | 45.5 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.076 m² (22.3 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.263%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 47.89 V | 12 | 20 |
| 0°C / 32°F Freezing / Mild Winter | 51.04 V | 11 | 19 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 52.3 V | 11 | 19 |
| -20°C / -4°F Northeast / Midwest Winter | 53.56 V | 11 | 18 |
| -30°C / -22°F Northern Plains / Mountain | 54.82 V | 10 | 18 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 15 panels | 6.00 kW | 335 sq ft (31.1 m²) |
| 8 kW | 20 panels | 8.00 kW | 447 sq ft (41.5 m²) |
| 10 kW | 25 panels | 10.00 kW | 559 sq ft (51.9 m²) |
| 12 kW | 30 panels | 12.00 kW | 670 sq ft (62.3 m²) |
Compatible CEC-Listed Inverters for Q.PEAK DUO L-G6.3/BGT 400
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–11 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 7–9 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ6PLUS-ACB-LL | Microinverter | 0.27 kW | 95.5% | 1:1 micro pairing (1.48 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 3–15 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 5–9 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-MS-US30 | String | 4.968 kW | 96.5% | 5–9 panels/string at -10°C | Verify Pair |
Other Power Classes in This Qcells (Hanwha) Series (9 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| Q.PEAK DUO L-G6.3/BGT 405 | 405 W | 378 W | 48.14 V | 10.65 A | 19.51% |
| Q.PEAK DUO L-G6.3/BGT 410 | 410 W | 382.8 W | 48.39 V | 10.7 A | 19.75% |
| Q.PEAK DUO L-G6.3/BGT 415 | 415 W | 387.6 W | 48.63 V | 10.74 A | 19.99% |
| Q.PEAK DUO L-G6.3/BGT 420 | 420 W | 392.3 W | 48.88 V | 10.79 A | 20.23% |
| Q.PEAK DUO L-G6.3/BGT 425 | 425 W | 397.1 W | 49.13 V | 10.83 A | 20.47% |
| Q.PEAK DUO L-G6.3/BGT 430 | 430 W | 401.9 W | 49.38 V | 10.88 A | 20.71% |
| Q.PEAK DUO L-G6.3/BGT 435 | 435 W | 406.7 W | 49.63 V | 10.92 A | 20.95% |
| Q.PEAK DUO L-G6.3/BGT 440 | 440 W | 411.5 W | 49.87 V | 10.97 A | 21.19% |
Engineering FAQ — Qcells (Hanwha) Q.PEAK DUO L-G6.3/BGT 400
How many Qcells (Hanwha) Q.PEAK DUO L-G6.3/BGT 400 panels can fit in one 600V string?
At -10°C (14°F) ambient, the Q.PEAK DUO L-G6.3/BGT 400 open-circuit voltage rises from 47.89V to 52.3V (using βVoc -0.263%/°C), allowing up to 11 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Qcells (Hanwha) Q.PEAK DUO L-G6.3/BGT 400?
Rated at 400W STC, the Q.PEAK DUO L-G6.3/BGT 400 carries a 373.2W PTC rating (93.3% PTC/STC ratio) and 19.27% module efficiency across 2.076 m² (22.3 sq ft).
Is the Qcells (Hanwha) Q.PEAK DUO L-G6.3/BGT 400 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.