415 W, 144 half-cut cell monocrystalline module, white backsheet, 1000V or 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
415W / 387.1W
Efficiency
21.31%
Voc / Vmp
49.74V / 42.2V
Max String (600V)
11 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Qcells (Hanwha) |
|---|---|
| Model Number (MPN) | Q.PEAK DUO L-G7.3 415 |
| Cell Technology | Mono-c-Si · 144 cells |
| Nameplate Power (Pmax STC) | 415 W |
| Real-World Output (PTC) | 387.1 W (93.3% of STC) |
| Module Efficiency | 21.31% (213.1 W/m²) |
| Open-Circuit Voltage (Voc) | 49.74 V |
| Maximum Power Voltage (Vmp) | 42.2 V |
| Short-Circuit Current (Isc) | 10.32 A (NEC 1.25× = 12.90 A) |
| Maximum Power Current (Imp) | 9.83 A |
| Temp. Coeff. Power (γPmax) | -0.346 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.27 %/°C (Class Estimate — Verify Datasheet) |
| Temp. Coeff. Current (αIsc) | +0.034 %/°C |
| Nominal Cell Temp (NOCT) | 45.6 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6") |
| Surface Area | 1.947 m² (21.0 sq ft) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.27%/°C, class estimate) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 49.74 V | 12 | 20 |
| 0°C / 32°F Freezing / Mild Winter | 53.1 V | 11 | 18 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 54.44 V | 11 | 18 |
| -20°C / -4°F Northeast / Midwest Winter | 55.78 V | 10 | 17 |
| -30°C / -22°F Northern Plains / Mountain | 57.13 V | 10 | 17 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 15 panels | 6.22 kW | 314 sq ft (29.2 m²) |
| 8 kW | 20 panels | 8.30 kW | 419 sq ft (38.9 m²) |
| 10 kW | 25 panels | 10.38 kW | 524 sq ft (48.7 m²) |
| 12 kW | 29 panels | 12.04 kW | 608 sq ft (56.5 m²) |
Compatible CEC-Listed Inverters for Q.PEAK DUO L-G7.3 415
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–11 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 6–8 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ6PLUS-ACB-LL | Microinverter | 0.27 kW | 95.5% | 1:1 micro pairing (1.54 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 3–14 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 5–9 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-MS-US30 | String | 4.968 kW | 96.5% | 5–9 panels/string at -10°C | Verify Pair |
Other Power Classes in This Qcells (Hanwha) Series (7 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| Q.PEAK DUO L-G7.3 385 | 385 W | 358.4 W | 48.17 V | 10.05 A | 19.77% |
| Q.PEAK DUO L-G7.3 390 | 390 W | 363.1 W | 48.44 V | 10.1 A | 20.03% |
| Q.PEAK DUO L-G7.3 395 | 395 W | 367.9 W | 48.7 V | 10.14 A | 20.29% |
| Q.PEAK DUO L-G7.3 400 | 400 W | 372.7 W | 48.96 V | 10.19 A | 20.54% |
| Q.PEAK DUO L-G7.3 405 | 405 W | 377.5 W | 49.22 V | 10.23 A | 20.8% |
| Q.PEAK DUO L-G7.3 410 | 410 W | 382.3 W | 49.48 V | 10.28 A | 21.06% |
Engineering FAQ — Qcells (Hanwha) Q.PEAK DUO L-G7.3 415
How many Qcells (Hanwha) Q.PEAK DUO L-G7.3 415 panels can fit in one 600V string?
At -10°C (14°F) ambient, the Q.PEAK DUO L-G7.3 415 open-circuit voltage rises from 49.74V to 54.44V (using βVoc -0.27%/°C), allowing up to 11 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Qcells (Hanwha) Q.PEAK DUO L-G7.3 415?
Rated at 415W STC, the Q.PEAK DUO L-G7.3 415 carries a 387.1W PTC rating (93.3% PTC/STC ratio) and 21.31% module efficiency across 1.947 m² (21.0 sq ft).
Is the Qcells (Hanwha) Q.PEAK DUO L-G7.3 415 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.