REC Solar REC330NP Black
330 W, 120 half cut cell monocrystalline module, black backsheet, 1000V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
330W / 308.3W
Efficiency
20.37%
Voc / Vmp
41V / 34.6V
Max String (600V)
13 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | REC Solar |
|---|---|
| Model Number (MPN) | REC330NP Black |
| Cell Technology | Mono-c-Si · 120 cells |
| Nameplate Power (Pmax STC) | 330 W |
| Real-World Output (PTC) | 308.3 W (93.4% of STC) |
| Module Efficiency | 20.37% (203.7 W/m²) |
| Open-Circuit Voltage (Voc) | 41 V |
| Maximum Power Voltage (Vmp) | 34.6 V |
| Short-Circuit Current (Isc) | 10.33 A (NEC 1.25× = 12.91 A) |
| Maximum Power Current (Imp) | 9.55 A |
| Temp. Coeff. Power (γPmax) | -0.352 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.267 %/°C |
| Temp. Coeff. Current (αIsc) | +0.036 %/°C |
| Nominal Cell Temp (NOCT) | 44.5 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 1.62 m² (17.4 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.267%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 41 V | 14 | 24 |
| 0°C / 32°F Freezing / Mild Winter | 43.74 V | 13 | 22 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 44.83 V | 13 | 22 |
| -20°C / -4°F Northeast / Midwest Winter | 45.93 V | 13 | 21 |
| -30°C / -22°F Northern Plains / Mountain | 47.02 V | 12 | 21 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 19 panels | 6.27 kW | 331 sq ft (30.8 m²) |
| 8 kW | 25 panels | 8.25 kW | 436 sq ft (40.5 m²) |
| 10 kW | 31 panels | 10.23 kW | 541 sq ft (50.2 m²) |
| 12 kW | 37 panels | 12.21 kW | 645 sq ft (59.9 m²) |
Compatible CEC-Listed Inverters for REC330NP Black
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–13 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 8–10 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ6PLUS-ACB-LL | Microinverter | 0.27 kW | 95.5% | 1:1 micro pairing (1.22 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 4–17 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 6–11 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-MS-US30 | String | 4.968 kW | 96.5% | 6–11 panels/string at -10°C | Verify Pair |
Other Power Classes in This REC Solar Series (6 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| REC305NP Black | 305 W | 284.4 W | 39.3 V | 10.06 A | 18.83% |
| REC310NP Black | 310 W | 289.2 W | 39.7 V | 10.12 A | 19.14% |
| REC315NP Black | 315 W | 294 W | 40.5 V | 10.09 A | 19.44% |
| REC320NP Black | 320 W | 298.8 W | 40.8 V | 10.18 A | 19.79% |
| REC325NP Black | 325 W | 303.5 W | 40.7 V | 10.28 A | 20.06% |
Engineering FAQ — REC Solar REC330NP Black
How many REC Solar REC330NP Black panels can fit in one 600V string?
At -10°C (14°F) ambient, the REC330NP Black open-circuit voltage rises from 41V to 44.83V (using βVoc -0.267%/°C), allowing up to 13 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the REC Solar REC330NP Black?
Rated at 330W STC, the REC330NP Black carries a 308.3W PTC rating (93.4% PTC/STC ratio) and 20.37% module efficiency across 1.62 m² (17.4 sq ft).
Is the REC Solar REC330NP Black listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.