380 W, 120 half-cut cell monocrystalline module, white backsheet, 1000V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
380W / 358.2W
Efficiency
21.47%
Voc / Vmp
41.4V / 35.3V
Max String (600V)
13 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | REC Solar |
|---|---|
| Model Number (MPN) | REC380NP2 |
| Cell Technology | Mono-c-Si · 120 cells |
| Nameplate Power (Pmax STC) | 380 W |
| Real-World Output (PTC) | 358.2 W (94.3% of STC) |
| Module Efficiency | 21.47% (214.7 W/m²) |
| Open-Circuit Voltage (Voc) | 41.4 V |
| Maximum Power Voltage (Vmp) | 35.3 V |
| Short-Circuit Current (Isc) | 11.51 A (NEC 1.25× = 14.39 A) |
| Maximum Power Current (Imp) | 10.77 A |
| Temp. Coeff. Power (γPmax) | -0.323 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.252 %/°C |
| Temp. Coeff. Current (αIsc) | +0.036 %/°C |
| Nominal Cell Temp (NOCT) | 43.9 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 1.77 m² (19.1 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.252%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 41.4 V | 14 | 24 |
| 0°C / 32°F Freezing / Mild Winter | 44.01 V | 13 | 22 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 45.05 V | 13 | 22 |
| -20°C / -4°F Northeast / Midwest Winter | 46.09 V | 13 | 21 |
| -30°C / -22°F Northern Plains / Mountain | 47.14 V | 12 | 21 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 16 panels | 6.08 kW | 305 sq ft (28.3 m²) |
| 8 kW | 22 panels | 8.36 kW | 419 sq ft (38.9 m²) |
| 10 kW | 27 panels | 10.26 kW | 514 sq ft (47.8 m²) |
| 12 kW | 32 panels | 12.16 kW | 610 sq ft (56.6 m²) |
Compatible CEC-Listed Inverters for REC380NP2
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–13 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 7–10 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ6PLUS-ACB-LL | Microinverter | 0.27 kW | 95.5% | 1:1 micro pairing (1.41 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 4–17 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 6–11 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-MS-US30 | String | 4.968 kW | 96.5% | 6–11 panels/string at -10°C | Verify Pair |
Other Power Classes in This REC Solar Series (8 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| REC345NP2 | 345 W | 324.5 W | 40.4 V | 11.19 A | 19.49% |
| REC350NP2 | 350 W | 329.3 W | 40.6 V | 11.22 A | 19.77% |
| REC355NP2 | 355 W | 334.1 W | 40.7 V | 11.27 A | 20.06% |
| REC360NP2 | 360 W | 338.9 W | 40.8 V | 11.31 A | 20.34% |
| REC365NP2 | 365 W | 343.7 W | 40.9 V | 11.36 A | 20.62% |
| REC370NP2 | 370 W | 348.5 W | 41.1 V | 11.41 A | 20.9% |
| REC375NP2 | 375 W | 353.4 W | 41.3 V | 11.46 A | 21.19% |
Engineering FAQ — REC Solar REC380NP2
How many REC Solar REC380NP2 panels can fit in one 600V string?
At -10°C (14°F) ambient, the REC380NP2 open-circuit voltage rises from 41.4V to 45.05V (using βVoc -0.252%/°C), allowing up to 13 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the REC Solar REC380NP2?
Rated at 380W STC, the REC380NP2 carries a 358.2W PTC rating (94.3% PTC/STC ratio) and 21.47% module efficiency across 1.77 m² (19.1 sq ft).
Is the REC Solar REC380NP2 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.