REC Solar REC395NP 72
395 W, 144 half cut cell monocrystalline module, white backsheet, 1000V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
395W / 369.4W
Efficiency
20.29%
Voc / Vmp
49.3V / 40.5V
Max String (600V)
11 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | REC Solar |
|---|---|
| Model Number (MPN) | REC395NP 72 |
| Cell Technology | Mono-c-Si · 144 cells |
| Nameplate Power (Pmax STC) | 395 W |
| Real-World Output (PTC) | 369.4 W (93.5% of STC) |
| Module Efficiency | 20.29% (202.9 W/m²) |
| Open-Circuit Voltage (Voc) | 49.3 V |
| Maximum Power Voltage (Vmp) | 40.5 V |
| Short-Circuit Current (Isc) | 10.36 A (NEC 1.25× = 12.95 A) |
| Maximum Power Current (Imp) | 9.77 A |
| Temp. Coeff. Power (γPmax) | -0.348 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.266 %/°C |
| Temp. Coeff. Current (αIsc) | +0.031 %/°C |
| Nominal Cell Temp (NOCT) | 44.4 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6") |
| Surface Area | 1.947 m² (21.0 sq ft) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.266%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 49.3 V | 12 | 20 |
| 0°C / 32°F Freezing / Mild Winter | 52.58 V | 11 | 19 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 53.89 V | 11 | 18 |
| -20°C / -4°F Northeast / Midwest Winter | 55.2 V | 10 | 18 |
| -30°C / -22°F Northern Plains / Mountain | 56.51 V | 10 | 17 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 16 panels | 6.32 kW | 335 sq ft (31.2 m²) |
| 8 kW | 21 panels | 8.29 kW | 440 sq ft (40.9 m²) |
| 10 kW | 26 panels | 10.27 kW | 545 sq ft (50.6 m²) |
| 12 kW | 31 panels | 12.24 kW | 650 sq ft (60.4 m²) |
Compatible CEC-Listed Inverters for REC395NP 72
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–11 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ6PLUS-ACB-LL | Microinverter | 0.27 kW | 95.5% | 1:1 micro pairing (1.46 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 3–14 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 5–9 panels/string at -10°C | Verify Pair |
| Growatt SPH 4600TL BL-US | Hybrid | 4.598 kW | 95% | 6–8 panels/string at -10°C | Verify Pair |
| Growatt MIN 6000TL-XH-US | Hybrid | 5.918 kW | 97% | 5–8 panels/string at -10°C | Verify Pair |
Other Power Classes in This REC Solar Series (8 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| REC365NP 72 | 365 W | 340.7 W | 47.4 V | 10.12 A | 18.75% |
| REC370NP 72 | 370 W | 345.5 W | 47.7 V | 10.16 A | 19% |
| REC375NP 72 | 375 W | 350.3 W | 48.1 V | 10.2 A | 19.26% |
| REC380NP 72 | 380 W | 355.1 W | 48.5 V | 10.24 A | 19.52% |
| REC385NP 72 | 385 W | 359.9 W | 48.9 V | 10.28 A | 19.77% |
| REC390NP 72 | 390 W | 364.6 W | 49.1 V | 10.32 A | 20.03% |
| REC400NP 72 | 400 W | 374.2 W | 49.4 V | 10.4 A | 20.54% |
Engineering FAQ — REC Solar REC395NP 72
How many REC Solar REC395NP 72 panels can fit in one 600V string?
At -10°C (14°F) ambient, the REC395NP 72 open-circuit voltage rises from 49.3V to 53.89V (using βVoc -0.266%/°C), allowing up to 11 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the REC Solar REC395NP 72?
Rated at 395W STC, the REC395NP 72 carries a 369.4W PTC rating (93.5% PTC/STC ratio) and 20.29% module efficiency across 1.947 m² (21.0 sq ft).
Is the REC Solar REC395NP 72 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.