REC Solar REC405TP3SM 72 XV
405 W, 144 half-cut cell monocrystalline module, white backsheet, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
405W / 379W
Efficiency
20.77%
Voc / Vmp
48.6V / 41.7V
Max String (600V)
11 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | REC Solar |
|---|---|
| Model Number (MPN) | REC405TP3SM 72 XV |
| Cell Technology | Mono-c-Si · 144 cells |
| Nameplate Power (Pmax STC) | 405 W |
| Real-World Output (PTC) | 379 W (93.6% of STC) |
| Module Efficiency | 20.77% (207.7 W/m²) |
| Open-Circuit Voltage (Voc) | 48.6 V |
| Maximum Power Voltage (Vmp) | 41.7 V |
| Short-Circuit Current (Isc) | 10.44 A (NEC 1.25× = 13.05 A) |
| Maximum Power Current (Imp) | 9.72 A |
| Temp. Coeff. Power (γPmax) | -0.341 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.265 %/°C |
| Temp. Coeff. Current (αIsc) | +0.033 %/°C |
| Nominal Cell Temp (NOCT) | 44.8 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6") |
| Surface Area | 1.95 m² (21.0 sq ft) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.265%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 48.6 V | 12 | 20 |
| 0°C / 32°F Freezing / Mild Winter | 51.82 V | 11 | 19 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 53.11 V | 11 | 18 |
| -20°C / -4°F Northeast / Midwest Winter | 54.4 V | 11 | 18 |
| -30°C / -22°F Northern Plains / Mountain | 55.68 V | 10 | 17 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 15 panels | 6.08 kW | 315 sq ft (29.3 m²) |
| 8 kW | 20 panels | 8.10 kW | 420 sq ft (39.0 m²) |
| 10 kW | 25 panels | 10.13 kW | 525 sq ft (48.8 m²) |
| 12 kW | 30 panels | 12.15 kW | 630 sq ft (58.5 m²) |
Compatible CEC-Listed Inverters for REC405TP3SM 72 XV
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–11 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 6–9 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ6PLUS-ACB-LL | Microinverter | 0.27 kW | 95.5% | 1:1 micro pairing (1.50 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 3–15 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 5–9 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-MS-US30 | String | 4.968 kW | 96.5% | 5–9 panels/string at -10°C | Verify Pair |
Other Power Classes in This REC Solar Series (6 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| REC380TP3SM 72 XV | 380 W | 355 W | 46.9 V | 10.3 A | 19.49% |
| REC385TP3SM 72 XV | 385 W | 359.8 W | 47.2 V | 10.33 A | 19.74% |
| REC390TP3SM 72 XV | 390 W | 364.6 W | 47.6 V | 10.35 A | 20% |
| REC395TP3SM 72 XV | 395 W | 369.4 W | 47.9 V | 10.38 A | 20.26% |
| REC400TP3SM 72 XV | 400 W | 374.2 W | 48.2 V | 10.42 A | 20.51% |
Engineering FAQ — REC Solar REC405TP3SM 72 XV
How many REC Solar REC405TP3SM 72 XV panels can fit in one 600V string?
At -10°C (14°F) ambient, the REC405TP3SM 72 XV open-circuit voltage rises from 48.6V to 53.11V (using βVoc -0.265%/°C), allowing up to 11 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the REC Solar REC405TP3SM 72 XV?
Rated at 405W STC, the REC405TP3SM 72 XV carries a 379W PTC rating (93.6% PTC/STC ratio) and 20.77% module efficiency across 1.95 m² (21.0 sq ft).
Is the REC Solar REC405TP3SM 72 XV listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.