RECOM SILLIA RCM-385-6MA
385 W, 72 cell monocrystalline module, white backsheet, 1500V or 1000V or 600V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
385W / 357.7W
Efficiency
20.05%
Voc / Vmp
48.65V / 39.9V
Max String (600V)
11 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | RECOM SILLIA |
|---|---|
| Model Number (MPN) | RCM-385-6MA |
| Cell Technology | Mono-c-Si · 72 cells |
| Nameplate Power (Pmax STC) | 385 W |
| Real-World Output (PTC) | 357.7 W (92.9% of STC) |
| Module Efficiency | 20.05% (200.5 W/m²) |
| Open-Circuit Voltage (Voc) | 48.65 V |
| Maximum Power Voltage (Vmp) | 39.9 V |
| Short-Circuit Current (Isc) | 9.95 A (NEC 1.25× = 12.44 A) |
| Maximum Power Current (Imp) | 9.65 A |
| Temp. Coeff. Power (γPmax) | -0.371 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.297 %/°C |
| Temp. Coeff. Current (αIsc) | +0.08 %/°C |
| Nominal Cell Temp (NOCT) | 44.8 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6") |
| Surface Area | 1.92 m² (20.7 sq ft) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.297%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 48.65 V | 12 | 20 |
| 0°C / 32°F Freezing / Mild Winter | 52.26 V | 11 | 19 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 53.71 V | 11 | 18 |
| -20°C / -4°F Northeast / Midwest Winter | 55.15 V | 10 | 18 |
| -30°C / -22°F Northern Plains / Mountain | 56.6 V | 10 | 17 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 16 panels | 6.16 kW | 331 sq ft (30.7 m²) |
| 8 kW | 21 panels | 8.09 kW | 434 sq ft (40.3 m²) |
| 10 kW | 26 panels | 10.01 kW | 537 sq ft (49.9 m²) |
| 12 kW | 32 panels | 12.32 kW | 661 sq ft (61.4 m²) |
Compatible CEC-Listed Inverters for RCM-385-6MA
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–11 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ6PLUS-ACB-LL | Microinverter | 0.27 kW | 95.5% | 1:1 micro pairing (1.43 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 3–14 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 5–9 panels/string at -10°C | Verify Pair |
| Growatt SPH 4000TL BL-US | Hybrid | 3.988 kW | 95% | 6–8 panels/string at -10°C | Verify Pair |
| Growatt SPH 4600TL BL-US | Hybrid | 4.598 kW | 95% | 6–8 panels/string at -10°C | Verify Pair |
Other Power Classes in This RECOM SILLIA Series (8 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| RCM-350-6MA | 350 W | 320.7 W | 47.35 V | 9.6 A | 18.23% |
| RCM-355-6MA | 355 W | 325.4 W | 47.45 V | 9.65 A | 18.49% |
| RCM-360-6MA | 360 W | 330.1 W | 47.65 V | 9.7 A | 18.75% |
| RCM-365-6MA | 365 W | 334.8 W | 47.85 V | 9.75 A | 19.01% |
| RCM-370-6MA | 370 W | 339.6 W | 48.05 V | 9.8 A | 19.27% |
| RCM-375-6MA | 375 W | 348.2 W | 48.25 V | 9.85 A | 19.53% |
| RCM-380-6MA | 380 W | 353 W | 48.45 V | 9.9 A | 19.79% |
Engineering FAQ — RECOM SILLIA RCM-385-6MA
How many RECOM SILLIA RCM-385-6MA panels can fit in one 600V string?
At -10°C (14°F) ambient, the RCM-385-6MA open-circuit voltage rises from 48.65V to 53.71V (using βVoc -0.297%/°C), allowing up to 11 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the RECOM SILLIA RCM-385-6MA?
Rated at 385W STC, the RCM-385-6MA carries a 357.7W PTC rating (92.9% PTC/STC ratio) and 20.05% module efficiency across 1.92 m² (20.7 sq ft).
Is the RECOM SILLIA RCM-385-6MA listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.