RNG International RSP400D-BK-108
400 W, 108 cell monocrystalline module, white backsheet, black frame, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
400W / 377.2W
Efficiency
20.62%
Voc / Vmp
37.16V / 31.02V
Max String (600V)
14 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | RNG International |
|---|---|
| Model Number (MPN) | RSP400D-BK-108 |
| Cell Technology | Mono-c-Si · 108 cells |
| Nameplate Power (Pmax STC) | 400 W |
| Real-World Output (PTC) | 377.2 W (94.3% of STC) |
| Module Efficiency | 20.62% (206.2 W/m²) |
| Open-Circuit Voltage (Voc) | 37.16 V |
| Maximum Power Voltage (Vmp) | 31.02 V |
| Short-Circuit Current (Isc) | 13.76 A (NEC 1.25× = 17.20 A) |
| Maximum Power Current (Imp) | 12.92 A |
| Temp. Coeff. Power (γPmax) | -0.328 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.289 %/°C |
| Temp. Coeff. Current (αIsc) | +0.035 %/°C |
| Nominal Cell Temp (NOCT) | 43.2 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6") |
| Surface Area | 1.94 m² (20.9 sq ft) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.289%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 37.16 V | 16 | 26 |
| 0°C / 32°F Freezing / Mild Winter | 39.84 V | 15 | 25 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 40.92 V | 14 | 24 |
| -20°C / -4°F Northeast / Midwest Winter | 41.99 V | 14 | 23 |
| -30°C / -22°F Northern Plains / Mountain | 43.07 V | 13 | 23 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 15 panels | 6.00 kW | 313 sq ft (29.1 m²) |
| 8 kW | 20 panels | 8.00 kW | 418 sq ft (38.8 m²) |
| 10 kW | 25 panels | 10.00 kW | 522 sq ft (48.5 m²) |
| 12 kW | 30 panels | 12.00 kW | 626 sq ft (58.2 m²) |
Compatible CEC-Listed Inverters for RSP400D-BK-108
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–14 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 8–11 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ6PLUS-ACB-LL | Microinverter | 0.27 kW | 95.5% | 1:1 micro pairing (1.48 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 4–19 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–12 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 4–12 panels/string at -10°C | Verify Pair |
Other Power Classes in This RNG International Series (5 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| RSP405D-BK-108 | 405 W | 382 W | 37.31 V | 13.87 A | 20.88% |
| RSP410D-BK-108 | 410 W | 386.9 W | 37.46 V | 13.96 A | 21.13% |
| RSP415D-BK-108 | 415 W | 391.7 W | 37.54 V | 14.12 A | 21.39% |
| RSP420D-BK-108 | 420 W | 396.5 W | 37.62 V | 14.26 A | 21.65% |
Engineering FAQ — RNG International RSP400D-BK-108
How many RNG International RSP400D-BK-108 panels can fit in one 600V string?
At -10°C (14°F) ambient, the RSP400D-BK-108 open-circuit voltage rises from 37.16V to 40.92V (using βVoc -0.289%/°C), allowing up to 14 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the RNG International RSP400D-BK-108?
Rated at 400W STC, the RSP400D-BK-108 carries a 377.2W PTC rating (94.3% PTC/STC ratio) and 20.62% module efficiency across 1.94 m² (20.9 sq ft).
Is the RNG International RSP400D-BK-108 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.