Dual glass modules, Mono-Si Perc module, 1000 Vdc maximum system voltage. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
135W / 124.3W
Efficiency
16.46%
Voc / Vmp
16.4V / 13.9V
Max String (600V)
33 @ −10°C
System Design Actions
Reference Datasheet Only: This module is not marked for new US residential kit builds. Compare CEC-listed US equivalents below.
View CEC-Listed Equivalents →Run String Voltage Check →
Electrical & Thermal Specifications (STC)
| Manufacturer | Solar Frame Solutions |
|---|---|
| Model Number (MPN) | SFS135T |
| Cell Technology | Mono-c-Si · 60 cells |
| Nameplate Power (Pmax STC) | 135 W |
| Real-World Output (PTC) | 124.3 W (92.1% of STC) |
| Module Efficiency | 16.46% (164.6 W/m²) |
| Open-Circuit Voltage (Voc) | 16.4 V |
| Maximum Power Voltage (Vmp) | 13.9 V |
| Short-Circuit Current (Isc) | 10.28 A (NEC 1.25× = 12.85 A) |
| Maximum Power Current (Imp) | 9.72 A |
| Temp. Coeff. Power (γPmax) | -0.395 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.266 %/°C |
| Temp. Coeff. Current (αIsc) | +0.04 %/°C |
| Nominal Cell Temp (NOCT) | 44.5 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 0.82 m² (8.8 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.266%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 16.4 V | 36 | 60 |
| 0°C / 32°F Freezing / Mild Winter | 17.49 V | 34 | 57 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 17.93 V | 33 | 55 |
| -20°C / -4°F Northeast / Midwest Winter | 18.36 V | 32 | 54 |
| -30°C / -22°F Northern Plains / Mountain | 18.8 V | 31 | 53 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 45 panels | 6.08 kW | 397 sq ft (36.9 m²) |
| 8 kW | 60 panels | 8.10 kW | 530 sq ft (49.2 m²) |
| 10 kW | 75 panels | 10.13 kW | 662 sq ft (61.5 m²) |
| 12 kW | 89 panels | 12.02 kW | 786 sq ft (73.0 m²) |
CEC-Listed US Equivalents to Solar Frame Solutions SFS135T
Looking to build a compliant US residential system with comparable wattage (135W) and efficiency? These CEC-listed UL 61730 models can be added straight to your kit:
Compatible CEC-Listed Inverters for SFS135T
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 4–33 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 14–26 panels/string at -10°C | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 7–44 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 11–27 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-MS-US30 | String | 4.968 kW | 96.5% | 11–27 panels/string at -10°C | Verify Pair |
Engineering FAQ — Solar Frame Solutions SFS135T
How many Solar Frame Solutions SFS135T panels can fit in one 600V string?
At -10°C (14°F) ambient, the SFS135T open-circuit voltage rises from 16.4V to 17.93V (using βVoc -0.266%/°C), allowing up to 33 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Solar Frame Solutions SFS135T?
Rated at 135W STC, the SFS135T carries a 124.3W PTC rating (92.1% PTC/STC ratio) and 16.46% module efficiency across 0.82 m² (8.8 sq ft).
Is the Solar Frame Solutions SFS135T listed in the CEC registry for US residential designs?
No — this model is categorized as CEC-Listed · Availability Not Checked (UL 61730). Homeowners in the US can compare active CEC-listed equivalents directly on this datasheet page.