Sonali Solar SS120H-365MD
365 W, 120 half-cut cell dual glass monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
365W / 341.9W
Efficiency
21.22%
Voc / Vmp
41.7V / 34.2V
Max String (600V)
13 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Sonali Solar |
|---|---|
| Model Number (MPN) | SS120H-365MD |
| Cell Technology | Mono-c-Si · 120 cells |
| Nameplate Power (Pmax STC) | 365 W |
| Real-World Output (PTC) | 341.9 W (93.7% of STC) |
| Module Efficiency | 21.22% (212.2 W/m²) |
| Open-Circuit Voltage (Voc) | 41.7 V |
| Maximum Power Voltage (Vmp) | 34.2 V |
| Short-Circuit Current (Isc) | 11.22 A (NEC 1.25× = 14.03 A) |
| Maximum Power Current (Imp) | 10.68 A |
| Temp. Coeff. Power (γPmax) | -0.364 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.282 %/°C |
| Temp. Coeff. Current (αIsc) | +0.05 %/°C |
| Nominal Cell Temp (NOCT) | 43.4 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 1.72 m² (18.5 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.282%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 41.7 V | 14 | 23 |
| 0°C / 32°F Freezing / Mild Winter | 44.64 V | 13 | 22 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 45.82 V | 13 | 21 |
| -20°C / -4°F Northeast / Midwest Winter | 46.99 V | 12 | 21 |
| -30°C / -22°F Northern Plains / Mountain | 48.17 V | 12 | 20 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 17 panels | 6.21 kW | 315 sq ft (29.2 m²) |
| 8 kW | 22 panels | 8.03 kW | 407 sq ft (37.8 m²) |
| 10 kW | 28 panels | 10.22 kW | 518 sq ft (48.2 m²) |
| 12 kW | 33 panels | 12.04 kW | 611 sq ft (56.8 m²) |
Compatible CEC-Listed Inverters for SS120H-365MD
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–13 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 8–10 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ6PLUS-ACB-LL | Microinverter | 0.27 kW | 95.5% | 1:1 micro pairing (1.35 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 4–17 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 6–10 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-MS-US30 | String | 4.968 kW | 96.5% | 6–10 panels/string at -10°C | Verify Pair |
Other Power Classes in This Sonali Solar Series (3 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| SS120H-370MD | 370 W | 346.8 W | 41.9 V | 11.29 A | 21.51% |
| SS120H-375MD | 375 W | 351.6 W | 42.1 V | 11.36 A | 21.8% |
Engineering FAQ — Sonali Solar SS120H-365MD
How many Sonali Solar SS120H-365MD panels can fit in one 600V string?
At -10°C (14°F) ambient, the SS120H-365MD open-circuit voltage rises from 41.7V to 45.82V (using βVoc -0.282%/°C), allowing up to 13 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Sonali Solar SS120H-365MD?
Rated at 365W STC, the SS120H-365MD carries a 341.9W PTC rating (93.7% PTC/STC ratio) and 21.22% module efficiency across 1.72 m² (18.5 sq ft).
Is the Sonali Solar SS120H-365MD listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.