Sonali Solar SS120H-485ND
485 W, 120 half-cut cell dual glass monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
485W / 460.3W
Efficiency
22.45%
Voc / Vmp
42.7V / 35.6V
Max String (600V)
12 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Sonali Solar |
|---|---|
| Model Number (MPN) | SS120H-485ND |
| Cell Technology | Mono-c-Si · 120 cells |
| Nameplate Power (Pmax STC) | 485 W |
| Real-World Output (PTC) | 460.3 W (94.9% of STC) |
| Module Efficiency | 22.45% (224.5 W/m²) |
| Open-Circuit Voltage (Voc) | 42.7 V |
| Maximum Power Voltage (Vmp) | 35.6 V |
| Short-Circuit Current (Isc) | 14.41 A (NEC 1.25× = 18.01 A) |
| Maximum Power Current (Imp) | 13.64 A |
| Temp. Coeff. Power (γPmax) | -0.299 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.24 %/°C |
| Temp. Coeff. Current (αIsc) | +0.041 %/°C |
| Nominal Cell Temp (NOCT) | 43.5 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.16 m² (23.3 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.24%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 42.7 V | 14 | 23 |
| 0°C / 32°F Freezing / Mild Winter | 45.26 V | 13 | 22 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 46.29 V | 12 | 21 |
| -20°C / -4°F Northeast / Midwest Winter | 47.31 V | 12 | 21 |
| -30°C / -22°F Northern Plains / Mountain | 48.34 V | 12 | 20 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 13 panels | 6.30 kW | 302 sq ft (28.1 m²) |
| 8 kW | 17 panels | 8.24 kW | 395 sq ft (36.7 m²) |
| 10 kW | 21 panels | 10.19 kW | 488 sq ft (45.4 m²) |
| 12 kW | 25 panels | 12.13 kW | 581 sq ft (54.0 m²) |
Compatible CEC-Listed Inverters for SS120H-485ND
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–12 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 7–10 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ7X-96-2-US | Microinverter | 0.315 kW | 97% | 1:1 micro pairing (1.54 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 4–17 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–10 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 4–10 panels/string at -10°C | Verify Pair |
Other Power Classes in This Sonali Solar Series (5 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| SS120H-465ND | 465 W | 440.9 W | 42.2 V | 14.07 A | 21.53% |
| SS120H-470ND | 470 W | 445.7 W | 42.4 V | 14.15 A | 21.76% |
| SS120H-475ND | 475 W | 450.6 W | 42.5 V | 14.23 A | 21.99% |
| SS120H-480ND | 480 W | 455.4 W | 42.6 V | 14.31 A | 22.22% |
Engineering FAQ — Sonali Solar SS120H-485ND
How many Sonali Solar SS120H-485ND panels can fit in one 600V string?
At -10°C (14°F) ambient, the SS120H-485ND open-circuit voltage rises from 42.7V to 46.29V (using βVoc -0.24%/°C), allowing up to 12 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Sonali Solar SS120H-485ND?
Rated at 485W STC, the SS120H-485ND carries a 460.3W PTC rating (94.9% PTC/STC ratio) and 22.45% module efficiency across 2.16 m² (23.3 sq ft).
Is the Sonali Solar SS120H-485ND listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.