Sonali Solar SS132H-480MT
480 W, 132 half-cut cell monocrystalline module, transparent backsheet, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
480W / 451.9W
Efficiency
20.25%
Voc / Vmp
45V / 37.8V
Max String (600V)
12 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Sonali Solar |
|---|---|
| Model Number (MPN) | SS132H-480MT |
| Cell Technology | Mono-c-Si · 132 cells |
| Nameplate Power (Pmax STC) | 480 W |
| Real-World Output (PTC) | 451.9 W (94.1% of STC) |
| Module Efficiency | 20.25% (202.5 W/m²) |
| Open-Circuit Voltage (Voc) | 45 V |
| Maximum Power Voltage (Vmp) | 37.8 V |
| Short-Circuit Current (Isc) | 13.59 A (NEC 1.25× = 16.99 A) |
| Maximum Power Current (Imp) | 12.71 A |
| Temp. Coeff. Power (γPmax) | -0.337 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.286 %/°C |
| Temp. Coeff. Current (αIsc) | +0.04 %/°C |
| Nominal Cell Temp (NOCT) | 43.1 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.37 m² (25.5 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.286%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 45 V | 13 | 22 |
| 0°C / 32°F Freezing / Mild Winter | 48.22 V | 12 | 20 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 49.5 V | 12 | 20 |
| -20°C / -4°F Northeast / Midwest Winter | 50.79 V | 11 | 19 |
| -30°C / -22°F Northern Plains / Mountain | 52.08 V | 11 | 19 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 13 panels | 6.24 kW | 332 sq ft (30.8 m²) |
| 8 kW | 17 panels | 8.16 kW | 434 sq ft (40.3 m²) |
| 10 kW | 21 panels | 10.08 kW | 536 sq ft (49.8 m²) |
| 12 kW | 25 panels | 12.00 kW | 638 sq ft (59.3 m²) |
Compatible CEC-Listed Inverters for SS132H-480MT
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–12 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 7–9 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ7X-96-2-US | Microinverter | 0.315 kW | 97% | 1:1 micro pairing (1.52 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 4–16 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–10 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 4–10 panels/string at -10°C | Verify Pair |
Other Power Classes in This Sonali Solar Series (6 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| SS132H-485MT | 485 W | 456.7 W | 45.1 V | 13.67 A | 20.46% |
| SS132H-490MT | 490 W | 461.5 W | 45.3 V | 13.74 A | 20.68% |
| SS132H-495MT | 495 W | 466.3 W | 45.4 V | 13.82 A | 20.89% |
| SS132H-500MT | 500 W | 471.2 W | 45.6 V | 13.9 A | 21.1% |
| SS132H-505MT | 505 W | 476 W | 45.7 V | 13.98 A | 21.31% |
Engineering FAQ — Sonali Solar SS132H-480MT
How many Sonali Solar SS132H-480MT panels can fit in one 600V string?
At -10°C (14°F) ambient, the SS132H-480MT open-circuit voltage rises from 45V to 49.5V (using βVoc -0.286%/°C), allowing up to 12 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Sonali Solar SS132H-480MT?
Rated at 480W STC, the SS132H-480MT carries a 451.9W PTC rating (94.1% PTC/STC ratio) and 20.25% module efficiency across 2.37 m² (25.5 sq ft).
Is the Sonali Solar SS132H-480MT listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.