535 W, 144 half-cut cell bifacial monodrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
535W / 496.2W
Efficiency
21.57%
Voc / Vmp
49.7V / 41.8V
Max String (600V)
10 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | SUNPLUS OPTIMUM |
|---|---|
| Model Number (MPN) | SR4-72HBD-535M |
| Cell Technology | Mono-c-Si (Bifacial) · 144 cells |
| Nameplate Power (Pmax STC) | 535 W |
| Real-World Output (PTC) | 496.2 W (92.7% of STC) |
| Module Efficiency | 21.57% (215.7 W/m²) |
| Open-Circuit Voltage (Voc) | 49.7 V |
| Maximum Power Voltage (Vmp) | 41.8 V |
| Short-Circuit Current (Isc) | 13.57 A (NEC 1.25× = 16.96 A) |
| Maximum Power Current (Imp) | 12.81 A |
| Temp. Coeff. Power (γPmax) | -0.375 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.284 %/°C |
| Temp. Coeff. Current (αIsc) | +0.048 %/°C |
| Nominal Cell Temp (NOCT) | 45.6 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.48 m² (26.7 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.284%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 49.7 V | 12 | 20 |
| 0°C / 32°F Freezing / Mild Winter | 53.23 V | 11 | 18 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 54.64 V | 10 | 18 |
| -20°C / -4°F Northeast / Midwest Winter | 56.05 V | 10 | 17 |
| -30°C / -22°F Northern Plains / Mountain | 57.46 V | 10 | 17 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 12 panels | 6.42 kW | 320 sq ft (29.8 m²) |
| 8 kW | 15 panels | 8.03 kW | 400 sq ft (37.2 m²) |
| 10 kW | 19 panels | 10.16 kW | 507 sq ft (47.1 m²) |
| 12 kW | 23 panels | 12.30 kW | 614 sq ft (57.0 m²) |
Compatible CEC-Listed Inverters for SR4-72HBD-535M
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–10 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 6–8 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8X-80-E-US | Microinverter | 0.384 kW | 97% | 1:1 micro pairing (1.39 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 3–14 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 3–9 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 3–9 panels/string at -10°C | Verify Pair |
Other Power Classes in This SUNPLUS OPTIMUM Series (6 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| SR4-72HBD-540M | 540 W | 501 W | 49.9 V | 13.66 A | 21.77% |
| SR4-72HBD-545M | 545 W | 505.8 W | 50.1 V | 13.75 A | 21.98% |
| SR4-72HBD-550M | 550 W | 510.6 W | 50.3 V | 13.82 A | 22.18% |
| SR4-72HBD-555M | 555 W | 515.4 W | 50.5 V | 13.89 A | 22.38% |
| SR4-72HBD-560M | 560 W | 520.2 W | 50.7 V | 13.96 A | 22.58% |
Engineering FAQ — SUNPLUS OPTIMUM SR4-72HBD-535M
How many SUNPLUS OPTIMUM SR4-72HBD-535M panels can fit in one 600V string?
At -10°C (14°F) ambient, the SR4-72HBD-535M open-circuit voltage rises from 49.7V to 54.64V (using βVoc -0.284%/°C), allowing up to 10 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the SUNPLUS OPTIMUM SR4-72HBD-535M?
Rated at 535W STC, the SR4-72HBD-535M carries a 496.2W PTC rating (92.7% PTC/STC ratio) and 21.57% module efficiency across 2.48 m² (26.7 sq ft).
Is the SUNPLUS OPTIMUM SR4-72HBD-535M listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.