635 W, 132 half-cut cell bifacial monodrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
635W / 589W
Efficiency
20.96%
Voc / Vmp
44.9V / 37.1V
Max String (600V)
12 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | SUNPLUS OPTIMUM |
|---|---|
| Model Number (MPN) | SR5-66HBD-635M |
| Cell Technology | Mono-c-Si (Bifacial) · 132 cells |
| Nameplate Power (Pmax STC) | 635 W |
| Real-World Output (PTC) | 589 W (92.8% of STC) |
| Module Efficiency | 20.96% (209.6 W/m²) |
| Open-Circuit Voltage (Voc) | 44.9 V |
| Maximum Power Voltage (Vmp) | 37.1 V |
| Short-Circuit Current (Isc) | 18.17 A (NEC 1.25× = 22.71 A) |
| Maximum Power Current (Imp) | 17.13 A |
| Temp. Coeff. Power (γPmax) | -0.386 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.291 %/°C |
| Temp. Coeff. Current (αIsc) | +0.05 %/°C |
| Nominal Cell Temp (NOCT) | 44.8 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 3.03 m² (32.6 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.291%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 44.9 V | 13 | 22 |
| 0°C / 32°F Freezing / Mild Winter | 48.17 V | 12 | 20 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 49.47 V | 12 | 20 |
| -20°C / -4°F Northeast / Midwest Winter | 50.78 V | 11 | 19 |
| -30°C / -22°F Northern Plains / Mountain | 52.09 V | 11 | 19 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 10 panels | 6.35 kW | 326 sq ft (30.3 m²) |
| 8 kW | 13 panels | 8.26 kW | 424 sq ft (39.4 m²) |
| 10 kW | 16 panels | 10.16 kW | 522 sq ft (48.5 m²) |
| 12 kW | 19 panels | 12.06 kW | 620 sq ft (57.6 m²) |
Compatible CEC-Listed Inverters for SR5-66HBD-635M
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–12 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 7–9 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8P-72-2-US | Microinverter | 0.475 kW | 97.5% | 1:1 micro pairing (1.34 DC/AC ratio) | Verify Pair |
| Fronius Symo 10.0-3 208-240 | String | 9.995 kW | 96.5% | 4–9 panels/string at -10°C | Verify Pair |
| GoodWe GEC6.0-1U-US20 | Hybrid | 6.01 kW | 96% | 4–10 panels/string at -10°C | Verify Pair |
| GoodWe GW6000-SBP-US20 | Hybrid | 6.01 kW | 96% | 4–10 panels/string at -10°C | Verify Pair |
Other Power Classes in This SUNPLUS OPTIMUM Series (8 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| SR5-66HBD-640M | 640 W | 593.7 W | 45.1 V | 18.22 A | 21.12% |
| SR5-66HBD-645M | 645 W | 598.5 W | 45.3 V | 18.27 A | 21.29% |
| SR5-66HBD-655M | 655 W | 608.1 W | 45.7 V | 18.37 A | 21.62% |
| SR5-66HBD-660M | 660 W | 612.9 W | 45.9 V | 18.42 A | 21.78% |
| SR5-66HBD-665M | 665 W | 617.7 W | 46.1 V | 18.47 A | 21.95% |
| SR5-66HBD-670M | 670 W | 622.5 W | 46.3 V | 18.52 A | 22.11% |
| SR5-66HBD-675M | 675 W | 627.2 W | 46.5 V | 18.57 A | 22.28% |
Engineering FAQ — SUNPLUS OPTIMUM SR5-66HBD-635M
How many SUNPLUS OPTIMUM SR5-66HBD-635M panels can fit in one 600V string?
At -10°C (14°F) ambient, the SR5-66HBD-635M open-circuit voltage rises from 44.9V to 49.47V (using βVoc -0.291%/°C), allowing up to 12 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the SUNPLUS OPTIMUM SR5-66HBD-635M?
Rated at 635W STC, the SR5-66HBD-635M carries a 589W PTC rating (92.8% PTC/STC ratio) and 20.96% module efficiency across 3.03 m² (32.6 sq ft).
Is the SUNPLUS OPTIMUM SR5-66HBD-635M listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.