SunSpark Technology SG6I72M-435
435 W, 144 half-cut cell bifacial monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
435W / 402.9W
Efficiency
20.05%
Voc / Vmp
49.8V / 41.4V
Max String (600V)
10 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | SunSpark Technology |
|---|---|
| Model Number (MPN) | SG6I72M-435 |
| Cell Technology | Mono-c-Si (Bifacial) · 144 cells |
| Nameplate Power (Pmax STC) | 435 W |
| Real-World Output (PTC) | 402.9 W (92.6% of STC) |
| Module Efficiency | 20.05% (200.5 W/m²) |
| Open-Circuit Voltage (Voc) | 49.8 V |
| Maximum Power Voltage (Vmp) | 41.4 V |
| Short-Circuit Current (Isc) | 11.16 A (NEC 1.25× = 13.95 A) |
| Maximum Power Current (Imp) | 10.51 A |
| Temp. Coeff. Power (γPmax) | -0.377 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.298 %/°C |
| Temp. Coeff. Current (αIsc) | +0.075 %/°C |
| Nominal Cell Temp (NOCT) | 45.3 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.17 m² (23.4 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.298%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 49.8 V | 12 | 20 |
| 0°C / 32°F Freezing / Mild Winter | 53.51 V | 11 | 18 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 54.99 V | 10 | 18 |
| -20°C / -4°F Northeast / Midwest Winter | 56.48 V | 10 | 17 |
| -30°C / -22°F Northern Plains / Mountain | 57.96 V | 10 | 17 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 14 panels | 6.09 kW | 327 sq ft (30.4 m²) |
| 8 kW | 19 panels | 8.27 kW | 444 sq ft (41.2 m²) |
| 10 kW | 23 panels | 10.01 kW | 537 sq ft (49.9 m²) |
| 12 kW | 28 panels | 12.18 kW | 654 sq ft (60.8 m²) |
Compatible CEC-Listed Inverters for SG6I72M-435
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–10 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 6–8 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ7X-96-2-US | Microinverter | 0.315 kW | 97% | 1:1 micro pairing (1.38 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 3–14 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 5–9 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-MS-US30 | String | 4.968 kW | 96.5% | 5–9 panels/string at -10°C | Verify Pair |
Other Power Classes in This SunSpark Technology Series (6 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| SG6I72M-440 | 440 W | 407.7 W | 50 V | 11.22 A | 20.28% |
| SG6I72M-445 | 445 W | 412.4 W | 50.2 V | 11.29 A | 20.51% |
| SG6I72M-450 | 450 W | 417.2 W | 50.4 V | 11.36 A | 20.74% |
| SG6I72M-455 | 455 W | 422 W | 50.6 V | 11.43 A | 20.97% |
| SG6I72M-460 | 460 W | 426.7 W | 50.8 V | 11.5 A | 21.2% |
Engineering FAQ — SunSpark Technology SG6I72M-435
How many SunSpark Technology SG6I72M-435 panels can fit in one 600V string?
At -10°C (14°F) ambient, the SG6I72M-435 open-circuit voltage rises from 49.8V to 54.99V (using βVoc -0.298%/°C), allowing up to 10 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the SunSpark Technology SG6I72M-435?
Rated at 435W STC, the SG6I72M-435 carries a 402.9W PTC rating (92.6% PTC/STC ratio) and 20.05% module efficiency across 2.17 m² (23.4 sq ft).
Is the SunSpark Technology SG6I72M-435 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.