SunTegra STS-114M-B4U
114 W, 24 cell monocrystalline shingle module, black backsheet, 600V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
114W / 98.9W
Efficiency
17.27%
Voc / Vmp
15.52V / 12.78V
Max String (600V)
35 @ −10°C
System Design Actions
Reference Datasheet Only: This module is not marked for new US residential kit builds. Compare CEC-listed US equivalents below.
View CEC-Listed Equivalents →Run String Voltage Check →
Electrical & Thermal Specifications (STC)
| Manufacturer | SunTegra |
|---|---|
| Model Number (MPN) | STS-114M-B4U |
| Cell Technology | Mono-c-Si · 60 cells |
| Nameplate Power (Pmax STC) | 114 W |
| Real-World Output (PTC) | 98.9 W (86.8% of STC) |
| Module Efficiency | 17.27% (172.7 W/m²) |
| Open-Circuit Voltage (Voc) | 15.52 V |
| Maximum Power Voltage (Vmp) | 12.78 V |
| Short-Circuit Current (Isc) | 9.68 A (NEC 1.25× = 12.10 A) |
| Maximum Power Current (Imp) | 8.92 A |
| Temp. Coeff. Power (γPmax) | -0.404 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.291 %/°C |
| Temp. Coeff. Current (αIsc) | +0.038 %/°C |
| Nominal Cell Temp (NOCT) | 57.3 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 0.66 m² (7.1 sq ft) (Est.) |
| Safety Listing | UL 1703 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.291%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 15.52 V | 38 | 64 |
| 0°C / 32°F Freezing / Mild Winter | 16.65 V | 36 | 60 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 17.1 V | 35 | 58 |
| -20°C / -4°F Northeast / Midwest Winter | 17.55 V | 34 | 56 |
| -30°C / -22°F Northern Plains / Mountain | 18 V | 33 | 55 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 53 panels | 6.04 kW | 377 sq ft (35.0 m²) |
| 8 kW | 71 panels | 8.09 kW | 504 sq ft (46.9 m²) |
| 10 kW | 88 panels | 10.03 kW | 625 sq ft (58.1 m²) |
| 12 kW | 106 panels | 12.08 kW | 753 sq ft (70.0 m²) |
CEC-Listed US Equivalents to SunTegra STS-114M-B4U
Looking to build a compliant US residential system with comparable wattage (114W) and efficiency? These CEC-listed UL 61730 models can be added straight to your kit:
Compatible CEC-Listed Inverters for STS-114M-B4U
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 4–35 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 14–28 panels/string at -10°C | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 7–46 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 11–29 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-MS-US30 | String | 4.968 kW | 96.5% | 11–29 panels/string at -10°C | Verify Pair |
Engineering FAQ — SunTegra STS-114M-B4U
How many SunTegra STS-114M-B4U panels can fit in one 600V string?
At -10°C (14°F) ambient, the STS-114M-B4U open-circuit voltage rises from 15.52V to 17.1V (using βVoc -0.291%/°C), allowing up to 35 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the SunTegra STS-114M-B4U?
Rated at 114W STC, the STS-114M-B4U carries a 98.9W PTC rating (86.8% PTC/STC ratio) and 17.27% module efficiency across 0.66 m² (7.1 sq ft).
Is the SunTegra STS-114M-B4U listed in the CEC registry for US residential designs?
No — this model is categorized as Legacy / Replacement Reference (UL 1703). Homeowners in the US can compare active CEC-listed equivalents directly on this datasheet page.