485 W, 108 half-cut cell double glass bifacial monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
485W / 460.8W
Efficiency
22.05%
Voc / Vmp
39.2V / 32.68V
Max String (600V)
14 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Thornova Solar |
|---|---|
| Model Number (MPN) | TS-BGT54(485)-G12R |
| Cell Technology | Mono-c-Si (Bifacial) · 108 cells |
| Nameplate Power (Pmax STC) | 485 W |
| Real-World Output (PTC) | 460.8 W (95% of STC) |
| Module Efficiency | 22.05% (220.5 W/m²) |
| Open-Circuit Voltage (Voc) | 39.2 V |
| Maximum Power Voltage (Vmp) | 32.68 V |
| Short-Circuit Current (Isc) | 15.77 A (NEC 1.25× = 19.71 A) |
| Maximum Power Current (Imp) | 14.85 A |
| Temp. Coeff. Power (γPmax) | -0.295 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.22 %/°C |
| Temp. Coeff. Current (αIsc) | +0.045 %/°C |
| Nominal Cell Temp (NOCT) | 43.2 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.2 m² (23.7 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.22%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 39.2 V | 15 | 25 |
| 0°C / 32°F Freezing / Mild Winter | 41.36 V | 14 | 24 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 42.22 V | 14 | 23 |
| -20°C / -4°F Northeast / Midwest Winter | 43.08 V | 13 | 23 |
| -30°C / -22°F Northern Plains / Mountain | 43.94 V | 13 | 22 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 13 panels | 6.30 kW | 308 sq ft (28.6 m²) |
| 8 kW | 17 panels | 8.24 kW | 403 sq ft (37.4 m²) |
| 10 kW | 21 panels | 10.19 kW | 497 sq ft (46.2 m²) |
| 12 kW | 25 panels | 12.13 kW | 592 sq ft (55.0 m²) |
Compatible CEC-Listed Inverters for TS-BGT54(485)-G12R
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–14 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 8–11 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ7X-96-2-US | Microinverter | 0.315 kW | 97% | 1:1 micro pairing (1.54 DC/AC ratio) | Verify Pair |
| Fronius Primo GEN24 6.0 208-240 Plus SC | Hybrid | 6.005 kW | 97% | 5–14 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–11 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 4–11 panels/string at -10°C | Verify Pair |
Other Power Classes in This Thornova Solar Series (5 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| TS-BGT54(490)-G12R | 490 W | 465.6 W | 39.5 V | 15.8 A | 22.27% |
| TS-BGT54(495)-G12R | 495 W | 470.5 W | 39.8 V | 15.83 A | 22.5% |
| TS-BGT54(500)-G12R | 500 W | 475.4 W | 40.1 V | 15.86 A | 22.73% |
| TS-BGT54(505)-G12R | 505 W | 480.2 W | 40.4 V | 15.89 A | 22.95% |
Engineering FAQ — Thornova Solar TS-BGT54(485)-G12R
How many Thornova Solar TS-BGT54(485)-G12R panels can fit in one 600V string?
At -10°C (14°F) ambient, the TS-BGT54(485)-G12R open-circuit voltage rises from 39.2V to 42.22V (using βVoc -0.22%/°C), allowing up to 14 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Thornova Solar TS-BGT54(485)-G12R?
Rated at 485W STC, the TS-BGT54(485)-G12R carries a 460.8W PTC rating (95% PTC/STC ratio) and 22.05% module efficiency across 2.2 m² (23.7 sq ft).
Is the Thornova Solar TS-BGT54(485)-G12R listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.