Toledo Solar TS1 (115W)
115 W, CdTe thin film module. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
115W / 106.8W
Efficiency
15.97%
Voc / Vmp
87.1V / 69V
Max String (600V)
6 @ −10°C
System Design Actions
Reference Datasheet Only: This module is not marked for new US residential kit builds. Compare CEC-listed US equivalents below.
View CEC-Listed Equivalents →Run String Voltage Check →
Electrical & Thermal Specifications (STC)
| Manufacturer | Toledo Solar |
|---|---|
| Model Number (MPN) | TS1 |
| Cell Technology | CdTe · 108 cells |
| Nameplate Power (Pmax STC) | 115 W |
| Real-World Output (PTC) | 106.8 W (92.9% of STC) |
| Module Efficiency | 15.97% (159.7 W/m²) |
| Open-Circuit Voltage (Voc) | 87.1 V |
| Maximum Power Voltage (Vmp) | 69 V |
| Short-Circuit Current (Isc) | 1.81 A (NEC 1.25× = 2.26 A) |
| Maximum Power Current (Imp) | 1.7 A |
| Temp. Coeff. Power (γPmax) | -0.326 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.302 %/°C |
| Temp. Coeff. Current (αIsc) | +0.034 %/°C |
| Nominal Cell Temp (NOCT) | 46.1 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 0.72 m² (7.8 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.302%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 87.1 V | 6 | 11 |
| 0°C / 32°F Freezing / Mild Winter | 93.68 V | 6 | 10 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 96.31 V | 6 | 10 |
| -20°C / -4°F Northeast / Midwest Winter | 98.94 V | 6 | 10 |
| -30°C / -22°F Northern Plains / Mountain | 101.57 V | 5 | 9 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 53 panels | 6.09 kW | 411 sq ft (38.2 m²) |
| 8 kW | 70 panels | 8.05 kW | 543 sq ft (50.4 m²) |
| 10 kW | 87 panels | 10.01 kW | 674 sq ft (62.6 m²) |
| 12 kW | 105 panels | 12.07 kW | 814 sq ft (75.6 m²) |
CEC-Listed US Equivalents to Toledo Solar TS1
Looking to build a compliant US residential system with comparable wattage (115W) and efficiency? These CEC-listed UL 61730 models can be added straight to your kit:
Compatible CEC-Listed Inverters for TS1
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 1–6 panels/string at -10°C | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 2–8 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 3–5 panels/string at -10°C | Verify Pair |
| Growatt 4000MTLP-US | String | 4.05 kW | 96% | 2–5 panels/string at -10°C | Verify Pair |
| Growatt 5000MTLP-US | String | 5.07 kW | 96% | 2–5 panels/string at -10°C | Verify Pair |
Engineering FAQ — Toledo Solar TS1
How many Toledo Solar TS1 panels can fit in one 600V string?
At -10°C (14°F) ambient, the TS1 open-circuit voltage rises from 87.1V to 96.31V (using βVoc -0.302%/°C), allowing up to 6 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Toledo Solar TS1?
Rated at 115W STC, the TS1 carries a 106.8W PTC rating (92.9% PTC/STC ratio) and 15.97% module efficiency across 0.72 m² (7.8 sq ft).
Is the Toledo Solar TS1 listed in the CEC registry for US residential designs?
No — this model is categorized as CEC-Listed · Availability Not Checked (UL 61730). Homeowners in the US can compare active CEC-listed equivalents directly on this datasheet page.