Trina Solar TSM-450NEG9R.28 (Vertex S+ EU)
450W N-Type i-TOPCon Solar Panel (IEC 61215 / IEC 61730 (EU/AU)). Registry source: Manufacturer IEC Datasheet (Global Reference) · CEC listing date: · Registry snapshot: .
STC / PTC Power
450W / 415W
Efficiency
22.5%
Voc / Vmp
52.9V / 44.6V
Max String (600V)
10 @ −10°C
System Design Actions
Reference Datasheet Only: This module is not marked for new US residential kit builds. Compare CEC-listed US equivalents below.
View CEC-Listed Equivalents →Run String Voltage Check →
Electrical & Thermal Specifications (STC)
| Manufacturer | Trina Solar |
|---|---|
| Model Number (MPN) | TSM-450NEG9R.28 (Vertex S+ EU) |
| Cell Technology | N-Type i-TOPCon · 144 cells |
| Nameplate Power (Pmax STC) | 450 W |
| Real-World Output (PTC) | 415 W (92.2% of STC) |
| Module Efficiency | 22.5% (225.2 W/m²) |
| Open-Circuit Voltage (Voc) | 52.9 V |
| Maximum Power Voltage (Vmp) | 44.6 V |
| Short-Circuit Current (Isc) | 10.74 A (NEC 1.25× = 13.43 A) |
| Maximum Power Current (Imp) | 10.09 A |
| Temp. Coeff. Power (γPmax) | -0.29 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.24 %/°C |
| Temp. Coeff. Current (αIsc) | +0.04 %/°C |
| Nominal Cell Temp (NOCT) | 43 °C |
| Dimensions (L × W) | 1762 × 1134 mm (69.4" × 44.6") |
| Surface Area | 1.998 m² (21.5 sq ft) |
| Safety Listing | IEC 61215 / IEC 61730 (EU/AU) |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.24%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 52.9 V | 11 | 18 |
| 0°C / 32°F Freezing / Mild Winter | 56.07 V | 10 | 17 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 57.34 V | 10 | 17 |
| -20°C / -4°F Northeast / Midwest Winter | 58.61 V | 10 | 17 |
| -30°C / -22°F Northern Plains / Mountain | 59.88 V | 10 | 16 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 14 panels | 6.30 kW | 301 sq ft (28.0 m²) |
| 8 kW | 18 panels | 8.10 kW | 387 sq ft (36.0 m²) |
| 10 kW | 23 panels | 10.35 kW | 495 sq ft (46.0 m²) |
| 12 kW | 27 panels | 12.15 kW | 581 sq ft (53.9 m²) |
CEC-Listed US Equivalents to Trina Solar TSM-450NEG9R.28 (Vertex S+ EU)
Looking to build a compliant US residential system with comparable wattage (450W) and efficiency? These CEC-listed UL 61730 models can be added straight to your kit:
CEC-Listed · Residential450 W
Zhejiang Sunpro Power Technology · UL 61730
SPDG450-N108M10
Efficiency: 23.68%
Compatible CEC-Listed Inverters for TSM-450NEG9R.28 (Vertex S+ EU)
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–10 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 6–8 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ7X-96-2-US | Microinverter | 0.315 kW | 97% | 1:1 micro pairing (1.43 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 3–13 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 5–8 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-MS-US30 | String | 4.968 kW | 96.5% | 5–8 panels/string at -10°C | Verify Pair |
Engineering FAQ — Trina Solar TSM-450NEG9R.28 (Vertex S+ EU)
How many Trina Solar TSM-450NEG9R.28 (Vertex S+ EU) panels can fit in one 600V string?
At -10°C (14°F) ambient, the TSM-450NEG9R.28 (Vertex S+ EU) open-circuit voltage rises from 52.9V to 57.34V (using βVoc -0.24%/°C), allowing up to 10 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Trina Solar TSM-450NEG9R.28 (Vertex S+ EU)?
Rated at 450W STC, the TSM-450NEG9R.28 (Vertex S+ EU) carries a 415W PTC rating (92.2% PTC/STC ratio) and 22.5% module efficiency across 1.998 m² (21.5 sq ft).
Is the Trina Solar TSM-450NEG9R.28 (Vertex S+ EU) listed in the CEC registry for US residential designs?
No — this model is categorized as Global / Non-US Reference (IEC 61215 / IEC 61730 (EU/AU)). Homeowners in the US can compare active CEC-listed equivalents directly on this datasheet page.