United Energy UE465M-72HB
465 W, 144 half-cut cell monocrystalline module, black frame, black backsheet, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
465W / 433W
Efficiency
21.43%
Voc / Vmp
50.6V / 41.9V
Max String (600V)
10 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | United Energy |
|---|---|
| Model Number (MPN) | UE465M-72HB |
| Cell Technology | Mono-c-Si · 144 cells |
| Nameplate Power (Pmax STC) | 465 W |
| Real-World Output (PTC) | 433 W (93.1% of STC) |
| Module Efficiency | 21.43% (214.3 W/m²) |
| Open-Circuit Voltage (Voc) | 50.6 V |
| Maximum Power Voltage (Vmp) | 41.9 V |
| Short-Circuit Current (Isc) | 11.65 A (NEC 1.25× = 14.56 A) |
| Maximum Power Current (Imp) | 11.1 A |
| Temp. Coeff. Power (γPmax) | -0.345 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.272 %/°C |
| Temp. Coeff. Current (αIsc) | +0.05 %/°C |
| Nominal Cell Temp (NOCT) | 46.2 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.17 m² (23.4 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.272%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 50.6 V | 11 | 19 |
| 0°C / 32°F Freezing / Mild Winter | 54.04 V | 11 | 18 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 55.42 V | 10 | 18 |
| -20°C / -4°F Northeast / Midwest Winter | 56.79 V | 10 | 17 |
| -30°C / -22°F Northern Plains / Mountain | 58.17 V | 10 | 17 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 13 panels | 6.04 kW | 304 sq ft (28.2 m²) |
| 8 kW | 18 panels | 8.37 kW | 420 sq ft (39.1 m²) |
| 10 kW | 22 panels | 10.23 kW | 514 sq ft (47.7 m²) |
| 12 kW | 26 panels | 12.09 kW | 607 sq ft (56.4 m²) |
Compatible CEC-Listed Inverters for UE465M-72HB
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–10 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 6–8 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ7X-96-2-US | Microinverter | 0.315 kW | 97% | 1:1 micro pairing (1.48 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 3–14 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 5–9 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-MS-US30 | String | 4.968 kW | 96.5% | 5–9 panels/string at -10°C | Verify Pair |
Other Power Classes in This United Energy Series (19 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| UE435M-72HB | 435 W | 404.3 W | 49.4 V | 11.23 A | 20.05% |
| UE440M-72HB | 440 W | 409.1 W | 49.6 V | 11.3 A | 20.28% |
| UE445M-72HB | 445 W | 413.9 W | 49.8 V | 11.37 A | 20.51% |
| UE450M-72HB | 450 W | 418.6 W | 50 V | 11.44 A | 20.74% |
| UE455M-72HB | 455 W | 423.4 W | 50.2 V | 11.51 A | 20.97% |
| UE460M-72HB | 460 W | 428.2 W | 50.4 V | 11.58 A | 21.2% |
| UE470M-72HB | 470 W | 437.8 W | 50.8 V | 11.72 A | 21.66% |
| UE520M-72HB | 520 W | 488.3 W | 49.2 V | 13.54 A | 20.16% |
| UE525M-72HB | 525 W | 493.1 W | 49.3 V | 13.61 A | 20.35% |
| UE530M-72HB | 530 W | 498 W | 49.4 V | 13.68 A | 20.54% |
| UE535M-72HB | 535 W | 502.8 W | 49.5 V | 13.75 A | 20.74% |
| UE540M-72HB | 540 W | 507.6 W | 49.6 V | 13.82 A | 20.93% |
| UE545M-72HB | 545 W | 512.4 W | 49.7 V | 13.89 A | 21.12% |
| UE550M-72HB | 550 W | 517.2 W | 49.8 V | 13.96 A | 21.32% |
Engineering FAQ — United Energy UE465M-72HB
How many United Energy UE465M-72HB panels can fit in one 600V string?
At -10°C (14°F) ambient, the UE465M-72HB open-circuit voltage rises from 50.6V to 55.42V (using βVoc -0.272%/°C), allowing up to 10 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the United Energy UE465M-72HB?
Rated at 465W STC, the UE465M-72HB carries a 433W PTC rating (93.1% PTC/STC ratio) and 21.43% module efficiency across 2.17 m² (23.4 sq ft).
Is the United Energy UE465M-72HB listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.