Zebra Energy ZBR-310M
310 W Monocrystalline Module. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
310W / 280.4W
Efficiency
16%
Voc / Vmp
45V / 36.6V
Max String (600V)
11 @ −10°C
System Design Actions
Reference Datasheet Only: This module is not marked for new US residential kit builds. Compare CEC-listed US equivalents below.
View CEC-Listed Equivalents →Run String Voltage Check →
Electrical & Thermal Specifications (STC)
| Manufacturer | Zebra Energy |
|---|---|
| Model Number (MPN) | ZBR-310M |
| Cell Technology | Mono-c-Si · 72 cells |
| Nameplate Power (Pmax STC) | 310 W |
| Real-World Output (PTC) | 280.4 W (90.5% of STC) |
| Module Efficiency | 16% (160 W/m²) |
| Open-Circuit Voltage (Voc) | 45 V |
| Maximum Power Voltage (Vmp) | 36.6 V |
| Short-Circuit Current (Isc) | 9.06 A (NEC 1.25× = 11.33 A) |
| Maximum Power Current (Imp) | 8.47 A |
| Temp. Coeff. Power (γPmax) | -0.433 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.378 %/°C |
| Temp. Coeff. Current (αIsc) | +0.07 %/°C |
| Nominal Cell Temp (NOCT) | 46.3 °C |
| Dimensions (L × W) | 1957 × 990 mm (77.0" × 39.0") |
| Surface Area | 1.937 m² (20.8 sq ft) |
| Safety Listing | UL 1703 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.378%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 45 V | 13 | 22 |
| 0°C / 32°F Freezing / Mild Winter | 49.25 V | 12 | 20 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 50.95 V | 11 | 19 |
| -20°C / -4°F Northeast / Midwest Winter | 52.65 V | 11 | 18 |
| -30°C / -22°F Northern Plains / Mountain | 54.36 V | 11 | 18 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 20 panels | 6.20 kW | 417 sq ft (38.7 m²) |
| 8 kW | 26 panels | 8.06 kW | 542 sq ft (50.4 m²) |
| 10 kW | 33 panels | 10.23 kW | 688 sq ft (63.9 m²) |
| 12 kW | 39 panels | 12.09 kW | 813 sq ft (75.5 m²) |
CEC-Listed US Equivalents to Zebra Energy ZBR-310M
Looking to build a compliant US residential system with comparable wattage (310W) and efficiency? These CEC-listed UL 61730 models can be added straight to your kit:
Compatible CEC-Listed Inverters for ZBR-310M
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–11 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 7–9 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ7PD-84-2-US | Microinverter | 0.21 kW | 96.5% | 1:1 micro pairing (1.48 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 4–15 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 6–9 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-MS-US30 | String | 4.968 kW | 96.5% | 6–9 panels/string at -10°C | Verify Pair |
Other Power Classes in This Zebra Energy Series (6 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| ZBR-255M | 255 W | 230.6 W | 38.19 V | 8.94 A | 15.61% |
| ZBR-290M | 290 W | 261.9 W | 44.2 V | 8.78 A | 14.97% |
| ZBR-295M | 295 W | 266.5 W | 44.3 V | 8.88 A | 15.23% |
| ZBR-300M | 300 W | 271.1 W | 44.5 V | 8.9 A | 15.48% |
| ZBR-305M | 305 W | 275.8 W | 44.8 V | 8.97 A | 15.74% |
Engineering FAQ — Zebra Energy ZBR-310M
How many Zebra Energy ZBR-310M panels can fit in one 600V string?
At -10°C (14°F) ambient, the ZBR-310M open-circuit voltage rises from 45V to 50.95V (using βVoc -0.378%/°C), allowing up to 11 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Zebra Energy ZBR-310M?
Rated at 310W STC, the ZBR-310M carries a 280.4W PTC rating (90.5% PTC/STC ratio) and 16% module efficiency across 1.937 m² (20.8 sq ft).
Is the Zebra Energy ZBR-310M listed in the CEC registry for US residential designs?
No — this model is categorized as Legacy / Replacement Reference (UL 1703). Homeowners in the US can compare active CEC-listed equivalents directly on this datasheet page.