Delta Electronics SOLIVIA 5.2 NA G4 TL (5.2 kW)
5200 W, 240 Vac transformerless Grid Support Utility Interactive Inverter. All the SOLIVIA models are same firmare version tested for Grid Support Utility Interactive type. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
5.2 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
100–500V / 500V
NEC 705.12 Breaker
30A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | Delta Electronics |
|---|---|
| Model Number (MPN) | SOLIVIA 5.2 NA G4 TL |
| Inverter Topology | String Inverter |
| Continuous AC Power (Paco) | 5.2 kW (5,200 W) |
| Nominal DC Input (Pdco) | 5,313 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| Listed Voltage Variants | 208V, 240V |
| CEC Weighted Efficiency | 97.5% |
| MPPT Operating Window | 100 – 500 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 500 Vdc |
| Max DC Input Current | 14 A |
| Night Tare Loss | 1.42 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | Yes |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 21.7 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 27.1 A |
| Minimum Standard Breaker | 30 A |
| Busbar Requirement | 200A Busbar (120% rule: up to 40A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (5.72–7.02 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 14–18 panels | 5.6–7.2 kW DC |
| 440W | 13–16 panels | 5.7–7.0 kW DC |
| 550W | 10–13 panels | 5.5–7.2 kW DC |
Compatible Solar Panels for Delta Electronics SOLIVIA 5.2 NA G4 TL
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 3–8 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 3–8 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 3–8 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 3–9 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 3–9 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 3–7 per string (-10°C) | Verify Pair |
Engineering FAQ — Delta Electronics SOLIVIA 5.2 NA G4 TL
What size circuit breaker does the Delta Electronics SOLIVIA 5.2 NA G4 TL require under NEC 705.12?
At 5.2 kW continuous AC output on 240V (21.7A continuous), the 125% continuous duty rule requires a minimum 30A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Delta Electronics SOLIVIA 5.2 NA G4 TL?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 5.2 kW unit with 5.72 kW to 7.02 kW DC of solar modules without exceeding 500V cold Voc.