DY CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Dyness TX11.4K-AM (11.519 kW)

11.4kW, 240Vac output,Bi-directional Transformerless Grid Support Utility Interactive Power Conversion Equipment. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
11.519 kW
CEC Weighted Eff.
97%
MPPT / Max DC
300–490V / 490V
NEC 705.12 Breaker
60A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Dyness TX11.4K-AM — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 300–490 Vdc 300V 490V MAX 490V PV DC INPUT ≤ 490V DC 11.519 kW · 97% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 60A BRKR

Electrical & Grid-Support Datasheet

Dyness TX11.4K-AM Electrical and Grid-Support Specifications
ManufacturerDyness
Model Number (MPN)TX11.4K-AM
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)11.519 kW (11,519 W)
Nominal DC Input (Pdco)11,973 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency97%
MPPT Operating Window300 – 490 Vdc (NREL SAM Measured)
Max DC Input Voltage490 Vdc
Max DC Input Current29.9 A
Night Tare Loss0.12 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for TX11.4K-AM
Max Continuous AC Current48 A @ 240V
125% Continuous Duty Current60.0 A
Minimum Standard Breaker60 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (12.67–15.55 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for TX11.4K-AM
Panel ClassRecommended QtyDC Array / Ratio
400W32–39 panels12.8–15.6 kW DC
440W29–35 panels12.8–15.4 kW DC
550W23–28 panels12.7–15.4 kW DC

Compatible Solar Panels for Dyness TX11.4K-AM

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Dyness TX11.4K-AM
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V8–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V8–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V8–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V9–9 per string (-10°C)Verify Pair
Mission Solar MSH10-550HT4T {B}550 W49.8 V9–9 per string (-10°C)Verify Pair
Trina Solar TSM-460NEG9RH.25460 W36.3 V12–12 per string (-10°C)Verify Pair

Engineering FAQ — Dyness TX11.4K-AM

What size circuit breaker does the Dyness TX11.4K-AM require under NEC 705.12?
At 11.519 kW continuous AC output on 240V (48A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Dyness TX11.4K-AM?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 11.519 kW unit with 12.67 kW to 15.55 kW DC of solar modules without exceeding 490V cold Voc.

More Dyness Inverters

TX9.6K-HM (9.648 kW)TX9.6K-AM (9.662 kW)TX11.4K-HM (11.498 kW)TX5K-AM (5.016 kW)TX5K-HM (5.02 kW)TX6K-HM (6.018 kW)All Dyness Equipment →