DY CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Dyness TX5K-AM (5.016 kW)

5kW, 240Vac output,Bi-directional Transformerless Grid Support Utility Interactive Power Conversion Equipment. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
5.016 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
130–490V / 490V
NEC 705.12 Breaker
30A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Dyness TX5K-AM — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 130–490 Vdc 130V 490V MAX 490V PV DC INPUT ≤ 490V DC 5.016 kW · 96.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 30A BRKR

Electrical & Grid-Support Datasheet

Dyness TX5K-AM Electrical and Grid-Support Specifications
ManufacturerDyness
Model Number (MPN)TX5K-AM
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)5.016 kW (5,016 W)
Nominal DC Input (Pdco)5,187 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window130 – 490 Vdc (NREL SAM Measured)
Max DC Input Voltage490 Vdc
Max DC Input Current13 A
Night Tare Loss0.12 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for TX5K-AM
Max Continuous AC Current20.9 A @ 240V
125% Continuous Duty Current26.1 A
Minimum Standard Breaker30 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (5.52–6.77 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for TX5K-AM
Panel ClassRecommended QtyDC Array / Ratio
400W14–17 panels5.6–6.8 kW DC
440W13–15 panels5.7–6.6 kW DC
550W10–12 panels5.5–6.6 kW DC

Compatible Solar Panels for Dyness TX5K-AM

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Dyness TX5K-AM
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V4–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V4–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V4–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V4–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V4–9 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V3–6 per string (-10°C)Verify Pair

Engineering FAQ — Dyness TX5K-AM

What size circuit breaker does the Dyness TX5K-AM require under NEC 705.12?
At 5.016 kW continuous AC output on 240V (20.9A continuous), the 125% continuous duty rule requires a minimum 30A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Dyness TX5K-AM?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 5.016 kW unit with 5.52 kW to 6.77 kW DC of solar modules without exceeding 490V cold Voc.

More Dyness Inverters

TX9.6K-AM (9.662 kW)TX11.4K-HM (11.498 kW)TX11.4K-AM (11.519 kW)TX5K-HM (5.02 kW)TX6K-HM (6.018 kW)TX6K-AM (6.028 kW)All Dyness Equipment →