Dyness TX5K-AM (5.016 kW)
5kW, 240Vac output,Bi-directional Transformerless Grid Support Utility Interactive Power Conversion Equipment. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
5.016 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
130–490V / 490V
NEC 705.12 Breaker
30A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | Dyness |
|---|---|
| Model Number (MPN) | TX5K-AM |
| Inverter Topology | Hybrid Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 5.016 kW (5,016 W) |
| Nominal DC Input (Pdco) | 5,187 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| CEC Weighted Efficiency | 96.5% (Class Estimate — Not listed in CEC) |
| MPPT Operating Window | 130 – 490 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 490 Vdc |
| Max DC Input Current | 13 A |
| Night Tare Loss | 0.12 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | CSA Group |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 20.9 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 26.1 A |
| Minimum Standard Breaker | 30 A |
| Busbar Requirement | 200A Busbar (120% rule: up to 40A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (5.52–6.77 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 14–17 panels | 5.6–6.8 kW DC |
| 440W | 13–15 panels | 5.7–6.6 kW DC |
| 550W | 10–12 panels | 5.5–6.6 kW DC |
Compatible Solar Panels for Dyness TX5K-AM
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 4–8 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 4–8 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 4–8 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 4–8 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 4–9 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 3–6 per string (-10°C) | Verify Pair |
Engineering FAQ — Dyness TX5K-AM
What size circuit breaker does the Dyness TX5K-AM require under NEC 705.12?
At 5.016 kW continuous AC output on 240V (20.9A continuous), the 125% continuous duty rule requires a minimum 30A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Dyness TX5K-AM?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 5.016 kW unit with 5.52 kW to 6.77 kW DC of solar modules without exceeding 490V cold Voc.