Fortress Power FP-Envy 15K (16.153 kW)

15 kW, 240 Vac Grid Support Hybrid Utility Interactive Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
16.153 kW
CEC Weighted Eff.
97%
MPPT / Max DC
250–440V / 440V
NEC 705.12 Breaker
90A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Fortress Power FP-Envy 15K — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 250–440 Vdc 250V 440V MAX 440V PV DC INPUT ≤ 440V DC 16.153 kW · 97% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 90A BRKR

Electrical & Grid-Support Datasheet

Fortress Power FP-Envy 15K Electrical and Grid-Support Specifications
ManufacturerFortress Power
Model Number (MPN)FP-Envy 15K
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)16.153 kW (16,153 W)
Nominal DC Input (Pdco)16,720 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency97%
MPPT Operating Window250 – 440 Vdc (NREL SAM Measured)
Max DC Input Voltage440 Vdc
Max DC Input Current46.4 A
Night Tare Loss29.36 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for FP-Envy 15K
Max Continuous AC Current67.3 A @ 240V
125% Continuous Duty Current84.1 A
Minimum Standard Breaker90 A
Busbar RequirementSupply-Side Tap (NEC 705.11) or 400A/Commercial Service

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (17.77–21.81 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for FP-Envy 15K
Panel ClassRecommended QtyDC Array / Ratio
400W44–55 panels17.6–22.0 kW DC
440W40–50 panels17.6–22.0 kW DC
550W32–40 panels17.6–22.0 kW DC

Compatible Solar Panels for Fortress Power FP-Envy 15K

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Fortress Power FP-Envy 15K
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V7–7 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V7–7 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V7–7 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–6 per string (-10°C)Verify Pair

Engineering FAQ — Fortress Power FP-Envy 15K

What size circuit breaker does the Fortress Power FP-Envy 15K require under NEC 705.12?
At 16.153 kW continuous AC output on 240V (67.3A continuous), the 125% continuous duty rule requires a minimum 90A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Fortress Power FP-Envy 15K?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 16.153 kW unit with 17.77 kW to 21.81 kW DC of solar modules without exceeding 440V cold Voc.

More Fortress Power Inverters

Avalon HV PC114 (11.406 kW)EdgeOn Duo 15 Pro (11.567 kW)FP-ENVY-12K (11.933 kW)Avalon HV PC50 (5.002 kW)EdgeOn Duo 7.5 (5.04 kW)EdgeOn Duo 9 (6.149 kW)All Fortress Power Equipment →