FP CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Fortress Power Avalon HV PC50 (5.002 kW)

5 kW, 240 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
5.002 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
140–450V / 450V
NEC 705.12 Breaker
30A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Fortress Power Avalon HV PC50 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 140–450 Vdc 140V 450V MAX 450V PV DC INPUT ≤ 450V DC 5.002 kW · 96.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 30A BRKR

Electrical & Grid-Support Datasheet

Fortress Power Avalon HV PC50 Electrical and Grid-Support Specifications
ManufacturerFortress Power
Model Number (MPN)Avalon HV PC50
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)5.002 kW (5,002 W)
Nominal DC Input (Pdco)5,166 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window140 – 450 Vdc (NREL SAM Measured)
Max DC Input Voltage450 Vdc
Max DC Input Current14 A
Night Tare Loss18.83 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for Avalon HV PC50
Max Continuous AC Current20.8 A @ 240V
125% Continuous Duty Current26.0 A
Minimum Standard Breaker30 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (5.5–6.75 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for Avalon HV PC50
Panel ClassRecommended QtyDC Array / Ratio
400W14–17 panels5.6–6.8 kW DC
440W13–15 panels5.7–6.6 kW DC
550W10–12 panels5.5–6.6 kW DC

Compatible Solar Panels for Fortress Power Avalon HV PC50

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Fortress Power Avalon HV PC50
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V4–7 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V4–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V4–7 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V4–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V4–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V3–6 per string (-10°C)Verify Pair

Engineering FAQ — Fortress Power Avalon HV PC50

What size circuit breaker does the Fortress Power Avalon HV PC50 require under NEC 705.12?
At 5.002 kW continuous AC output on 240V (20.8A continuous), the 125% continuous duty rule requires a minimum 30A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Fortress Power Avalon HV PC50?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 5.002 kW unit with 5.5 kW to 6.75 kW DC of solar modules without exceeding 450V cold Voc.

More Fortress Power Inverters

EdgeOn Duo 15 Pro (11.567 kW)FP-ENVY-12K (11.933 kW)FP-Envy 15K (16.153 kW)EdgeOn Duo 7.5 (5.04 kW)EdgeOn Duo 9 (6.149 kW)Avalon HV PC76 (7.604 kW)All Fortress Power Equipment →