FX CEC-Listed · Commercial / C&IMicroinverterUL 1741-SB (3rd Ed.)

FoxESS M1-600-NA (0.607 kW)

600 W, 208 Vac Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.607 kW
CEC Weighted Eff.
95%
MPPT / Max DC
35–50V / 50V
NEC 705.12 Breaker
15A @ 208V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
FoxESS M1-600-NA — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 35–50 Vdc 35V 50V MAX 50V PV DC INPUT ≤ 50V DC 0.607 kW · 95% CEC GRID-SUPPORT INVERTER AC OUTPUT 208V · 15A BRKR

Electrical & Grid-Support Datasheet

FoxESS M1-600-NA Electrical and Grid-Support Specifications
ManufacturerFoxESS
Model Number (MPN)M1-600-NA
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.607 kW (607 W)
Nominal DC Input (Pdco)637 W
Nominal AC Voltage208 Vac (3-Phase)
CEC Weighted Efficiency95%
MPPT Operating Window35 – 50 Vdc (NREL SAM Measured)
Max DC Input Voltage50 Vdc
Max DC Input Current15.2 A
Night Tare Loss0.31 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for M1-600-NA
Max Continuous AC Current1.7 A @ 208V
125% Continuous Duty Current2.1 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.67–0.82 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for M1-600-NA
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.66× DC/AC)
440W1 panel1:1 pairing (0.72× DC/AC)
550W1 panel1:1 pairing (0.91× DC/AC)

CEC-Listed 240V Equivalents to FoxESS M1-600-NA

Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (0.607 kW Microinverter) and can be added directly to your US System Kit:

CEC-Listed · 240V0.604 kW
Cherry Solution · Microinverter

CMI-600S-SA

CEC Efficiency: 96.5%
Datasheet →
CEC-Listed · 240V0.604 kW
HYXI Power · Microinverter

HYX-M600-S

CEC Efficiency: 96.5%
Datasheet →
CEC-Listed · 240V0.594 kW
SolaX Power · Microinverter

A1-Micro 600P

CEC Efficiency: 94%
Datasheet →

Compatible Solar Panels for FoxESS M1-600-NA

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for FoxESS M1-600-NA
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 VDC/AC 0.96 (1 panel/input)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 VDC/AC 0.96 (1 panel/input)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 VDC/AC 0.95 (1 panel/input)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 VDC/AC 0.92 (1 panel/input)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 VDC/AC 0.91 (1 panel/input)Verify Pair
Trina Solar TSM-565NE19RC565 W46.3 VDC/AC 0.93 (1 panel/input)Verify Pair

Engineering FAQ — FoxESS M1-600-NA

What size circuit breaker does the FoxESS M1-600-NA require under NEC 705.12?
At 0.607 kW continuous AC output on 208V (1.7A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the FoxESS M1-600-NA?
As a 607W microinverter, it pairs 1:1 with panels rated roughly 637W to 880W STC.

More FoxESS Inverters

AIO-H1-11.4-US (11.361 kW)AC1-11.4-US (11.44 kW)H1-11.4-US (11.512 kW)M1-800-NA (0.814 kW)M1-1000-NA (1.005 kW)M1-1200-NA (1.201 kW)All FoxESS Equipment →