Fronius official logoCEC-Listed · 240V ResidentialString

Fronius Primo 12.5-1 208-240 (12.5 kW)

12.5 kW, 240 Vac Grid Support Utility Interactive Inverter with arc detector and meter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
12.5 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
260–800V / 800V
NEC 705.12 Breaker
70A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Fronius Primo 12.5-1 208-240 — Real Fronius solar inverter installation
Real Fronius solar inverter installationWikimedia Commons — File:Bregenz-Vorarlberger Kraftwerke-Inverter Test bay-Fronius Ohmpilot 9 0-3-01ASD.jpg (CC BY-SA 4.0)
DC INPUT & MPPT TRACKING WINDOW (STRING) MPPT 260–800 Vdc 260V 800V MAX 800V PV DC INPUT ≤ 800V DC 12.5 kW · 96.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 70A BRKR

Electrical & Grid-Support Datasheet

Fronius Primo 12.5-1 208-240 Electrical and Grid-Support Specifications
ManufacturerFronius
Model Number (MPN)Primo 12.5-1 208-240
Inverter TopologyString Inverter
Continuous AC Power (Paco)12.5 kW (12,500 W)
Nominal DC Input (Pdco)12,867 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window260 – 800 Vdc (NREL SAM Measured)
Max DC Input Voltage800 Vdc
Max DC Input Current19.5 A
Night Tare Loss0.32 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for Primo 12.5-1 208-240
Max Continuous AC Current52.1 A @ 240V
125% Continuous Duty Current65.1 A
Minimum Standard Breaker70 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (13.75–16.88 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for Primo 12.5-1 208-240
Panel ClassRecommended QtyDC Array / Ratio
400W34–42 panels13.6–16.8 kW DC
440W31–38 panels13.6–16.7 kW DC
550W25–31 panels13.8–17.1 kW DC

Compatible Solar Panels for Fronius Primo 12.5-1 208-240

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Fronius Primo 12.5-1 208-240
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V7–14 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V7–14 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V7–13 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V8–14 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V8–14 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–11 per string (-10°C)Verify Pair

Engineering FAQ — Fronius Primo 12.5-1 208-240

What size circuit breaker does the Fronius Primo 12.5-1 208-240 require under NEC 705.12?
At 12.5 kW continuous AC output on 240V (52.1A continuous), the 125% continuous duty rule requires a minimum 70A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Fronius Primo 12.5-1 208-240?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 12.5 kW unit with 13.75 kW to 16.88 kW DC of solar modules without exceeding 800V cold Voc.

More Fronius Inverters

Primo 11.4-1 208-240 (11.4 kW)Symo 12.0-3 208-240 (12 kW)Symo Advanced 12.0-3 208-240 (12.09 kW)Primo 15.0-1 208-240 (15 kW)Primo 3.8-1 208-240 (3.8 kW)Primo GEN24 3.8 208-240 SC (3.8 kW)All Fronius Equipment →