Fronius Symo Advanced 12.0-3 208-240 (12.09 kW)
12 kW, 240 Vac, three phase Grid Support Utility Interactive Inverter with arc detector and meter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
12.09 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
300–480V / 480V
NEC 705.12 Breaker
70A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | Fronius |
|---|---|
| Model Number (MPN) | Symo Advanced 12.0-3 208-240 |
| Inverter Topology | String Inverter |
| Continuous AC Power (Paco) | 12.09 kW (12,090 W) |
| Nominal DC Input (Pdco) | 12,547 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| Listed Voltage Variants | 240V, 208V |
| CEC Weighted Efficiency | 96.5% (Class Estimate — Not listed in CEC) |
| MPPT Operating Window | 300 – 480 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 480 Vdc |
| Max DC Input Current | 33.9 A |
| Night Tare Loss | 0.8 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | Yes |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 50.4 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 63.0 A |
| Minimum Standard Breaker | 70 A |
| Busbar Requirement | 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (13.3–16.32 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 33–41 panels | 13.2–16.4 kW DC |
| 440W | 30–37 panels | 13.2–16.3 kW DC |
| 550W | 24–30 panels | 13.2–16.5 kW DC |
Compatible Solar Panels for Fronius Symo Advanced 12.0-3 208-240
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 8–8 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 8–8 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 8–8 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-520MB-AG | 520 W | 48.4 V | 9–9 per string (-10°C) | Verify Pair |
| Mission Solar MSX10-460HN0B {C} | 460 W | 39.3 V | 11–11 per string (-10°C) | Verify Pair |
| Trina Solar TSM-460NEG9RH.25 | 460 W | 36.3 V | 12–12 per string (-10°C) | Verify Pair |
Engineering FAQ — Fronius Symo Advanced 12.0-3 208-240
What size circuit breaker does the Fronius Symo Advanced 12.0-3 208-240 require under NEC 705.12?
At 12.09 kW continuous AC output on 240V (50.4A continuous), the 125% continuous duty rule requires a minimum 70A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Fronius Symo Advanced 12.0-3 208-240?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 12.09 kW unit with 13.3 kW to 16.32 kW DC of solar modules without exceeding 480V cold Voc.