Growatt 36000TL3-US (35.71 kW)
36 kW, 480 Vac, three phases, 3/N/PE, Transformerless Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
35.71 kW
CEC Weighted Eff.
98.5%
MPPT / Max DC
520–800V / 800V
NEC 705.12 Breaker
60A @ 480V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Growatt |
|---|---|
| Model Number (MPN) | 36000TL3-US |
| Inverter Topology | Commercial 3-Phase Inverter |
| Continuous AC Power (Paco) | 35.71 kW (35,710 W) |
| Nominal DC Input (Pdco) | 36,402 W |
| Nominal AC Voltage | 480 Vac (3-Phase) |
| CEC Weighted Efficiency | 98.5% |
| MPPT Operating Window | 520 – 800 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 800 Vdc |
| Max DC Input Current | 52 A |
| Night Tare Loss | 2.05 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 43 A @ 480V |
|---|---|
| 125% Continuous Duty Current | 53.8 A |
| Minimum Standard Breaker | 60 A |
| Busbar Requirement | 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (39.28–48.21 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 98–121 panels | 39.2–48.4 kW DC |
| 440W | 89–110 panels | 39.2–48.4 kW DC |
| 550W | 71–88 panels | 39.0–48.4 kW DC |
CEC-Listed 240V Equivalents to Growatt 36000TL3-US
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (35.71 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Compatible Solar Panels for Growatt 36000TL3-US
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 14–14 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 14–14 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-520MB-AG | 520 W | 48.4 V | 15–15 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 11–11 per string (-10°C) | Verify Pair |
| Trina Solar TSM-460NEG9RH.25 | 460 W | 36.3 V | 20–20 per string (-10°C) | Verify Pair |
| Mission Solar MSX10-445HN0B {C} | 445 W | 38.7 V | 19–19 per string (-10°C) | Verify Pair |
Engineering FAQ — Growatt 36000TL3-US
What size circuit breaker does the Growatt 36000TL3-US require under NEC 705.12?
At 35.71 kW continuous AC output on 480V (43A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Growatt 36000TL3-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 35.71 kW unit with 39.28 kW to 48.21 kW DC of solar modules without exceeding 800V cold Voc.