Growatt WIT 100K-A-US (99.389 kW)
100 kW, 480 Vac Grid Support Utility Interactive Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
99.389 kW
CEC Weighted Eff.
98%
MPPT / Max DC
750–900V / 900V
NEC 705.12 Breaker
150A @ 480V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Growatt |
|---|---|
| Model Number (MPN) | WIT 100K-A-US |
| Inverter Topology | Commercial 3-Phase Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 99.389 kW (99,389 W) |
| Nominal DC Input (Pdco) | 101,648 W |
| Nominal AC Voltage | 480 Vac (3-Phase) |
| CEC Weighted Efficiency | 98% |
| MPPT Operating Window | 750 – 900 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 900 Vdc |
| Max DC Input Current | 124.1 A |
| Night Tare Loss | 19.5 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Intertek |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 119.5 A @ 480V |
|---|---|
| 125% Continuous Duty Current | 149.4 A |
| Minimum Standard Breaker | 150 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (109.33–134.18 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 273–335 panels | 109.2–134.0 kW DC |
| 440W | 248–305 panels | 109.1–134.2 kW DC |
| 550W | 199–244 panels | 109.5–134.2 kW DC |
CEC-Listed 240V Equivalents to Growatt WIT 100K-A-US
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (99.389 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Engineering FAQ — Growatt WIT 100K-A-US
What size circuit breaker does the Growatt WIT 100K-A-US require under NEC 705.12?
At 99.389 kW continuous AC output on 480V (119.5A continuous), the 125% continuous duty rule requires a minimum 150A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Growatt WIT 100K-A-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 99.389 kW unit with 109.33 kW to 134.18 kW DC of solar modules without exceeding 900V cold Voc.