Growatt WIT 35K-A-US L2 (34.855 kW)
35 kW, 208 Vac Grid Support Utility Interactive Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
34.855 kW
CEC Weighted Eff.
97%
MPPT / Max DC
380–650V / 650V
NEC 705.12 Breaker
125A @ 208V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Growatt |
|---|---|
| Model Number (MPN) | WIT 35K-A-US L2 |
| Inverter Topology | Commercial 3-Phase Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 34.855 kW (34,855 W) |
| Nominal DC Input (Pdco) | 36,078 W |
| Nominal AC Voltage | 208 Vac (3-Phase) |
| CEC Weighted Efficiency | 97% |
| MPPT Operating Window | 380 – 650 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 650 Vdc |
| Max DC Input Current | 70.5 A |
| Night Tare Loss | 19.95 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Intertek |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 96.8 A @ 208V |
|---|---|
| 125% Continuous Duty Current | 121.0 A |
| Minimum Standard Breaker | 125 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (38.34–47.05 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 96–118 panels | 38.4–47.2 kW DC |
| 440W | 87–107 panels | 38.3–47.1 kW DC |
| 550W | 70–86 panels | 38.5–47.3 kW DC |
CEC-Listed 240V Equivalents to Growatt WIT 35K-A-US L2
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (34.855 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Compatible Solar Panels for Growatt WIT 35K-A-US L2
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 10–11 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 11–11 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 10–11 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 11–11 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 11–11 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 8–9 per string (-10°C) | Verify Pair |
Engineering FAQ — Growatt WIT 35K-A-US L2
What size circuit breaker does the Growatt WIT 35K-A-US L2 require under NEC 705.12?
At 34.855 kW continuous AC output on 208V (96.8A continuous), the 125% continuous duty rule requires a minimum 125A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Growatt WIT 35K-A-US L2?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 34.855 kW unit with 38.34 kW to 47.05 kW DC of solar modules without exceeding 650V cold Voc.