Growatt WIT 55K-H-US L2 (54.972 kW)
55 kW, 208 Vac Grid Support Utility Interactive Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
54.972 kW
CEC Weighted Eff.
94%
MPPT / Max DC
340–550V / 550V
NEC 705.12 Breaker
200A @ 208V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Growatt |
|---|---|
| Model Number (MPN) | WIT 55K-H-US L2 |
| Inverter Topology | Commercial 3-Phase Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 54.972 kW (54,972 W) |
| Nominal DC Input (Pdco) | 58,589 W |
| Nominal AC Voltage | 208 Vac (3-Phase) |
| CEC Weighted Efficiency | 94% |
| MPPT Operating Window | 340 – 550 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 550 Vdc |
| Max DC Input Current | 131.7 A |
| Night Tare Loss | 16.87 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Intertek |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 152.6 A @ 208V |
|---|---|
| 125% Continuous Duty Current | 190.8 A |
| Minimum Standard Breaker | 200 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (60.47–74.21 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 151–186 panels | 60.4–74.4 kW DC |
| 440W | 137–169 panels | 60.3–74.4 kW DC |
| 550W | 110–135 panels | 60.5–74.3 kW DC |
CEC-Listed 240V Equivalents to Growatt WIT 55K-H-US L2
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (54.972 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Compatible Solar Panels for Growatt WIT 55K-H-US L2
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 9–9 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 9–9 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 9–9 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 10–10 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 10–10 per string (-10°C) | Verify Pair |
| Trina Solar TSM-460NEG9RH.25 | 460 W | 36.3 V | 13–13 per string (-10°C) | Verify Pair |
Engineering FAQ — Growatt WIT 55K-H-US L2
What size circuit breaker does the Growatt WIT 55K-H-US L2 require under NEC 705.12?
At 54.972 kW continuous AC output on 208V (152.6A continuous), the 125% continuous duty rule requires a minimum 200A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Growatt WIT 55K-H-US L2?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 54.972 kW unit with 60.47 kW to 74.21 kW DC of solar modules without exceeding 550V cold Voc.