HM CEC-Listed · 240V ResidentialMicroinverter

Hoymiles HMS-700-2D-NA (0.697 kW)

696W, 240 Vac Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.697 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
33–48V / 48V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Hoymiles HMS-700-2D-NA — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 33–48 Vdc 33V 48V MAX 48V PV DC INPUT ≤ 48V DC 0.697 kW · 96.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

Hoymiles HMS-700-2D-NA Electrical and Grid-Support Specifications
ManufacturerHoymiles
Model Number (MPN)HMS-700-2D-NA
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.697 kW (697 W)
Nominal DC Input (Pdco)723 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window33 – 48 Vdc (NREL SAM Measured)
Max DC Input Voltage48 Vdc
Max DC Input Current17.2 A
Night Tare Loss0.11 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for HMS-700-2D-NA
Max Continuous AC Current2.9 A @ 240V
125% Continuous Duty Current3.6 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.77–0.94 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for HMS-700-2D-NA
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.57× DC/AC)
440W1 panel1:1 pairing (0.63× DC/AC)
550W1 panel1:1 pairing (0.79× DC/AC)

Engineering FAQ — Hoymiles HMS-700-2D-NA

What size circuit breaker does the Hoymiles HMS-700-2D-NA require under NEC 705.12?
At 0.697 kW continuous AC output on 240V (2.9A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Hoymiles HMS-700-2D-NA?
As a 697W microinverter, it pairs 1:1 with panels rated roughly 732W to 1011W STC.

More Hoymiles Inverters

HMS-700-2T-NA (0.642 kW)MIS-700-2NA (0.647 kW)HM-700N (0.697 kW)HMS-800-2T-NA (0.726 kW)MIS-800-2NA (0.73 kW)HM-800N (0.767 kW)All Hoymiles Equipment →