NEP (Northern Electric & Power) Neptune100K (99.368 kW)
100 kW, 480 Vac, 3-Phase Transformerless Grid Support Utility Interactive PV Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
99.368 kW
CEC Weighted Eff.
98%
MPPT / Max DC
550–850V / 850V
NEC 705.12 Breaker
150A @ 480V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | NEP (Northern Electric & Power) |
|---|---|
| Model Number (MPN) | Neptune100K |
| Inverter Topology | Commercial 3-Phase Inverter |
| Continuous AC Power (Paco) | 99.368 kW (99,368 W) |
| Nominal DC Input (Pdco) | 101,480 W |
| Nominal AC Voltage | 480 Vac (3-Phase) |
| CEC Weighted Efficiency | 98% |
| MPPT Operating Window | 550 – 850 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 850 Vdc |
| Max DC Input Current | 139 A |
| Night Tare Loss | 2 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | CSA Group |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 119.5 A @ 480V |
|---|---|
| 125% Continuous Duty Current | 149.4 A |
| Minimum Standard Breaker | 150 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (109.3–134.15 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 273–335 panels | 109.2–134.0 kW DC |
| 440W | 248–305 panels | 109.1–134.2 kW DC |
| 550W | 199–244 panels | 109.5–134.2 kW DC |
CEC-Listed 240V Equivalents to NEP (Northern Electric & Power) Neptune100K
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (99.368 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Compatible Solar Panels for NEP (Northern Electric & Power) Neptune100K
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 15–15 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 15–15 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-520MB-AG | 520 W | 48.4 V | 16–16 per string (-10°C) | Verify Pair |
| Trina Solar TSM-460NEG9RH.25 | 460 W | 36.3 V | 21–21 per string (-10°C) | Verify Pair |
| Mission Solar MSX10-445HN0B {C} | 445 W | 38.7 V | 20–20 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.TRON BLK M-G2.D+ 415 | 415 W | 38.47 V | 20–20 per string (-10°C) | Verify Pair |
Engineering FAQ — NEP (Northern Electric & Power) Neptune100K
What size circuit breaker does the NEP (Northern Electric & Power) Neptune100K require under NEC 705.12?
At 99.368 kW continuous AC output on 480V (119.5A continuous), the 125% continuous duty rule requires a minimum 150A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the NEP (Northern Electric & Power) Neptune100K?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 99.368 kW unit with 109.3 kW to 134.15 kW DC of solar modules without exceeding 850V cold Voc.