NEP (Northern Electric & Power) Neptune60K (59.898 kW)
60 kW, 480 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
59.898 kW
CEC Weighted Eff.
98.5%
MPPT / Max DC
580–850V / 850V
NEC 705.12 Breaker
90A @ 480V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | NEP (Northern Electric & Power) |
|---|---|
| Model Number (MPN) | Neptune60K |
| Inverter Topology | Commercial 3-Phase Inverter |
| Continuous AC Power (Paco) | 59.898 kW (59,898 W) |
| Nominal DC Input (Pdco) | 60,956 W |
| Nominal AC Voltage | 480 Vac (3-Phase) |
| CEC Weighted Efficiency | 98.5% |
| MPPT Operating Window | 580 – 850 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 850 Vdc |
| Max DC Input Current | 84.7 A |
| Night Tare Loss | 3.16 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | CSA Group |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 72 A @ 480V |
|---|---|
| 125% Continuous Duty Current | 90.0 A |
| Minimum Standard Breaker | 90 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (65.89–80.86 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 165–202 panels | 66.0–80.8 kW DC |
| 440W | 150–184 panels | 66.0–81.0 kW DC |
| 550W | 120–147 panels | 66.0–80.8 kW DC |
CEC-Listed 240V Equivalents to NEP (Northern Electric & Power) Neptune60K
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (59.898 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Compatible Solar Panels for NEP (Northern Electric & Power) Neptune60K
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Canadian Solar CS6.2-48TM-460H | 460 W | 36.2 V | 22–22 per string (-10°C) | Verify Pair |
| REC Solar REC430AA Pure 2 | 430 W | 49 V | 16–16 per string (-10°C) | Verify Pair |
| Maxeon / SunPower SPR-MAX3-420-BLK-R | 420 W | 40.73 V | 19–19 per string (-10°C) | Verify Pair |
Engineering FAQ — NEP (Northern Electric & Power) Neptune60K
What size circuit breaker does the NEP (Northern Electric & Power) Neptune60K require under NEC 705.12?
At 59.898 kW continuous AC output on 480V (72A continuous), the 125% continuous duty rule requires a minimum 90A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the NEP (Northern Electric & Power) Neptune60K?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 59.898 kW unit with 65.89 kW to 80.86 kW DC of solar modules without exceeding 850V cold Voc.