OutBack Power GS4048A (3.6 kW)
3.6 kW, 240 Vac Grid Support Utility Interactive Inverter with external battery backup and accessible neutral to allow 120 VAC loads to be backed up. Inverter is capable of PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
3.6 kW
CEC Weighted Eff.
92.5%
MPPT / Max DC
120–500V / 600V
NEC 705.12 Breaker
20A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | OutBack Power |
|---|---|
| Model Number (MPN) | GS4048A |
| Inverter Topology | Hybrid Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 3.6 kW (3,600 W) |
| Nominal DC Input (Pdco) | 3,847 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| CEC Weighted Efficiency | 92.5% |
| MPPT Operating Window | 120 – 500 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 600 Vdc |
| Max DC Input Current | 80.1 A |
| Night Tare Loss | 0.1 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | Yes |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 15 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 18.8 A |
| Minimum Standard Breaker | 20 A |
| Busbar Requirement | 100A Busbar (120% rule: up to 20A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (3.96–4.86 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 10–12 panels | 4.0–4.8 kW DC |
| 440W | 9–11 panels | 4.0–4.8 kW DC |
| 550W | 7–9 panels | 3.9–5.0 kW DC |
Compatible Solar Panels for OutBack Power GS4048A
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 4–10 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 4–10 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 4–10 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 4–10 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 4–11 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 3–8 per string (-10°C) | Verify Pair |
Engineering FAQ — OutBack Power GS4048A
What size circuit breaker does the OutBack Power GS4048A require under NEC 705.12?
At 3.6 kW continuous AC output on 240V (15A continuous), the 125% continuous duty rule requires a minimum 20A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the OutBack Power GS4048A?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 3.6 kW unit with 3.96 kW to 4.86 kW DC of solar modules without exceeding 600V cold Voc.