OB CEC-Listed · 240V ResidentialHybridBattery Hybrid

OutBack Power GS8048A (7.2 kW)

7.2 kW, 240 Vac Grid Support Utility Interactive Inverter with external battery backup and accessible neutral to allow 120 VAC loads to be backed up. Inverter is capable of PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
7.2 kW
CEC Weighted Eff.
92.5%
MPPT / Max DC
120–500V / 600V
NEC 705.12 Breaker
40A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
OutBack Power GS8048A — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 120–500 Vdc 120V 500V MAX 600V PV DC INPUT ≤ 600V DC 7.2 kW · 92.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 40A BRKR

Electrical & Grid-Support Datasheet

OutBack Power GS8048A Electrical and Grid-Support Specifications
ManufacturerOutBack Power
Model Number (MPN)GS8048A
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)7.2 kW (7,200 W)
Nominal DC Input (Pdco)8,841 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency92.5%
MPPT Operating Window120 – 500 Vdc (NREL SAM Measured)
Max DC Input Voltage600 Vdc
Max DC Input Current184.2 A
Night Tare Loss0.1 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for GS8048A
Max Continuous AC Current30 A @ 240V
125% Continuous Duty Current37.5 A
Minimum Standard Breaker40 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (7.92–9.72 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for GS8048A
Panel ClassRecommended QtyDC Array / Ratio
400W20–24 panels8.0–9.6 kW DC
440W18–22 panels7.9–9.7 kW DC
550W14–18 panels7.7–9.9 kW DC

Compatible Solar Panels for OutBack Power GS8048A

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for OutBack Power GS8048A
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V4–10 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V4–10 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V4–10 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V4–10 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V4–11 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V3–8 per string (-10°C)Verify Pair

Engineering FAQ — OutBack Power GS8048A

What size circuit breaker does the OutBack Power GS8048A require under NEC 705.12?
At 7.2 kW continuous AC output on 240V (30A continuous), the 125% continuous duty rule requires a minimum 40A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the OutBack Power GS8048A?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 7.2 kW unit with 7.92 kW to 9.72 kW DC of solar modules without exceeding 600V cold Voc.

More OutBack Power Inverters

OGHI8048A (7.638 kW)GS4048A (3.6 kW)SBX5048-120/240 (4.985 kW)All OutBack Power Equipment →