OB CEC-Listed · 240V ResidentialHybridBattery Hybrid

OutBack Power SBX5048-120/240 (4.985 kW)

5.0 kW, 240 Vac, Multimode Grid Support Utility Interactive PV and Battery Inverter with PCS Functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
4.985 kW
CEC Weighted Eff.
94%
MPPT / Max DC
250–550V / 550V
NEC 705.12 Breaker
30A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
OutBack Power SBX5048-120/240 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 250–550 Vdc 250V 550V MAX 550V PV DC INPUT ≤ 550V DC 4.985 kW · 94% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 30A BRKR

Electrical & Grid-Support Datasheet

OutBack Power SBX5048-120/240 Electrical and Grid-Support Specifications
ManufacturerOutBack Power
Model Number (MPN)SBX5048-120/240
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)4.985 kW (4,985 W)
Nominal DC Input (Pdco)5,278 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency94%
MPPT Operating Window250 – 550 Vdc (NREL SAM Measured)
Max DC Input Voltage550 Vdc
Max DC Input Current12.6 A
Night Tare Loss24.85 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SBX5048-120/240
Max Continuous AC Current20.8 A @ 240V
125% Continuous Duty Current26.0 A
Minimum Standard Breaker30 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (5.48–6.73 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SBX5048-120/240
Panel ClassRecommended QtyDC Array / Ratio
400W14–17 panels5.6–6.8 kW DC
440W12–15 panels5.3–6.6 kW DC
550W10–12 panels5.5–6.6 kW DC

Compatible Solar Panels for OutBack Power SBX5048-120/240

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for OutBack Power SBX5048-120/240
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V7–9 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V7–9 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V7–9 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–10 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–10 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–7 per string (-10°C)Verify Pair

Engineering FAQ — OutBack Power SBX5048-120/240

What size circuit breaker does the OutBack Power SBX5048-120/240 require under NEC 705.12?
At 4.985 kW continuous AC output on 240V (20.8A continuous), the 125% continuous duty rule requires a minimum 30A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the OutBack Power SBX5048-120/240?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 4.985 kW unit with 5.48 kW to 6.73 kW DC of solar modules without exceeding 550V cold Voc.