OB CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

OutBack Power OGHI8048A (7.638 kW)

7.2 kW, 240 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
7.638 kW
CEC Weighted Eff.
93%
MPPT / Max DC
120–500V / 600V
NEC 705.12 Breaker
40A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
OutBack Power OGHI8048A — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 120–500 Vdc 120V 500V MAX 600V PV DC INPUT ≤ 600V DC 7.638 kW · 93% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 40A BRKR

Electrical & Grid-Support Datasheet

OutBack Power OGHI8048A Electrical and Grid-Support Specifications
ManufacturerOutBack Power
Model Number (MPN)OGHI8048A
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)7.638 kW (7,638 W)
Nominal DC Input (Pdco)8,448 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency93%
MPPT Operating Window120 – 500 Vdc (NREL SAM Measured)
Max DC Input Voltage600 Vdc
Max DC Input Current176 A
Night Tare Loss146.4 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryUL
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for OGHI8048A
Max Continuous AC Current31.8 A @ 240V
125% Continuous Duty Current39.8 A
Minimum Standard Breaker40 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (8.4–10.31 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for OGHI8048A
Panel ClassRecommended QtyDC Array / Ratio
400W21–26 panels8.4–10.4 kW DC
440W19–23 panels8.4–10.1 kW DC
550W15–19 panels8.3–10.4 kW DC

Compatible Solar Panels for OutBack Power OGHI8048A

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for OutBack Power OGHI8048A
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V4–10 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V4–10 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V4–10 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V4–10 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V4–11 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V3–8 per string (-10°C)Verify Pair

Engineering FAQ — OutBack Power OGHI8048A

What size circuit breaker does the OutBack Power OGHI8048A require under NEC 705.12?
At 7.638 kW continuous AC output on 240V (31.8A continuous), the 125% continuous duty rule requires a minimum 40A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the OutBack Power OGHI8048A?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 7.638 kW unit with 8.4 kW to 10.31 kW DC of solar modules without exceeding 600V cold Voc.