SMA Solar official logoCEC-Listed · 240V ResidentialString

SMA Solar SB7.0-1TP-US-40 (7 kW)

7.0 kW, 240 Vac transformerless Grid Support Utility Interactive Inverter with revenue grade energy meter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
7 kW
CEC Weighted Eff.
97%
MPPT / Max DC
245–480V / 480V
NEC 705.12 Breaker
40A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
SMA Solar SB7.0-1TP-US-40 — Real SMA Sunny Boy solar inverter
Real SMA Sunny Boy solar inverterWikimedia Commons — File:Dornbirn-SMA Sunny Boy inverter SWR 3000-01ASD.jpg (CC BY-SA 4.0)
DC INPUT & MPPT TRACKING WINDOW (STRING) MPPT 245–480 Vdc 245V 480V MAX 480V PV DC INPUT ≤ 480V DC 7 kW · 97% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 40A BRKR

Electrical & Grid-Support Datasheet

SMA Solar SB7.0-1TP-US-40 Electrical and Grid-Support Specifications
ManufacturerSMA Solar
Model Number (MPN)SB7.0-1TP-US-40
Inverter TopologyString Inverter
Continuous AC Power (Paco)7 kW (7,000 W)
Nominal DC Input (Pdco)7,258 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency97%
MPPT Operating Window245 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current19.9 A
Night Tare Loss5.1 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SB7.0-1TP-US-40
Max Continuous AC Current29.2 A @ 240V
125% Continuous Duty Current36.5 A
Minimum Standard Breaker40 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (7.7–9.45 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SB7.0-1TP-US-40
Panel ClassRecommended QtyDC Array / Ratio
400W19–24 panels7.6–9.6 kW DC
440W18–21 panels7.9–9.2 kW DC
550W14–17 panels7.7–9.3 kW DC

Compatible Solar Panels for SMA Solar SB7.0-1TP-US-40

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for SMA Solar SB7.0-1TP-US-40
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V7–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V7–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V7–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–6 per string (-10°C)Verify Pair

Engineering FAQ — SMA Solar SB7.0-1TP-US-40

What size circuit breaker does the SMA Solar SB7.0-1TP-US-40 require under NEC 705.12?
At 7 kW continuous AC output on 240V (29.2A continuous), the 125% continuous duty rule requires a minimum 40A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the SMA Solar SB7.0-1TP-US-40?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 7 kW unit with 7.7 kW to 9.45 kW DC of solar modules without exceeding 480V cold Voc.

More SMA Solar Inverters

SB6.0-1SP-US-40 (6 kW)SBS6.0-US-10 (6 kW)SB7.0-1SP-US-40 (7 kW)SBSE7.7-US-50 (7.622 kW)SB7.7-1SP-US-40 (7.68 kW)SBSE9.6-US-50 (9.569 kW)All SMA Solar Equipment →