SMA Solar SC 2500-EV-US (2353.87 kW)
Sunny Central 2500 kW, 550 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
2353.87 kW
CEC Weighted Eff.
97%
MPPT / Max DC
850–1425V / 1425V
NEC 705.12 Breaker
3100A @ 550V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | SMA Solar |
|---|---|
| Model Number (MPN) | SC 2500-EV-US |
| Inverter Topology | Commercial 3-Phase Inverter |
| Continuous AC Power (Paco) | 2353.87 kW (2,353,870 W) |
| Nominal DC Input (Pdco) | 2,433,390 W |
| Nominal AC Voltage | 550 Vac (3-Phase) |
| CEC Weighted Efficiency | 97% |
| MPPT Operating Window | 850 – 1425 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 1425 Vdc |
| Max DC Input Current | 2448.1 A |
| Night Tare Loss | 370 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | Yes |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 2471 A @ 550V |
|---|---|
| 125% Continuous Duty Current | 3088.8 A |
| Minimum Standard Breaker | 3100 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (2589.26–3177.72 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 6473–7944 panels | 2589.2–3177.6 kW DC |
| 440W | 5885–7222 panels | 2589.4–3177.7 kW DC |
| 550W | 4708–5778 panels | 2589.4–3177.9 kW DC |
CEC-Listed 240V Equivalents to SMA Solar SC 2500-EV-US
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (2353.87 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Compatible Solar Panels for SMA Solar SC 2500-EV-US
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 23–25 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 23–25 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 23–24 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 24–26 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 24–26 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 18–20 per string (-10°C) | Verify Pair |
Engineering FAQ — SMA Solar SC 2500-EV-US
What size circuit breaker does the SMA Solar SC 2500-EV-US require under NEC 705.12?
At 2353.87 kW continuous AC output on 550V (2471A continuous), the 125% continuous duty rule requires a minimum 3100A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the SMA Solar SC 2500-EV-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 2353.87 kW unit with 2589.26 kW to 3177.72 kW DC of solar modules without exceeding 1425V cold Voc.