SMA Solar SC 4000 UP-US 600V 3850A (3650.134 kW)
4000 kVA, 600 Vac, 3 phase Grid Support Utility Interactive PV and Battery Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
3650.134 kW
CEC Weighted Eff.
98.5%
MPPT / Max DC
880–1200V / 1200V
NEC 705.12 Breaker
4400A @ 600V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | SMA Solar |
|---|---|
| Model Number (MPN) | SC 4000 UP-US 600V 3850A |
| Inverter Topology | Commercial 3-Phase Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 3650.134 kW (3,650,134 W) |
| Nominal DC Input (Pdco) | 3,722,110 W |
| Nominal AC Voltage | 600 Vac (3-Phase) |
| CEC Weighted Efficiency | 98.5% |
| MPPT Operating Window | 880 – 1200 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 1200 Vdc |
| Max DC Input Current | 3837.2 A |
| Night Tare Loss | 453.5 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 3512.4 A @ 600V |
|---|---|
| 125% Continuous Duty Current | 4390.5 A |
| Minimum Standard Breaker | 4400 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (4015.15–4927.68 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 10038–12319 panels | 4015.2–4927.6 kW DC |
| 440W | 9125–11199 panels | 4015.0–4927.6 kW DC |
| 550W | 7300–8959 panels | 4015.0–4927.4 kW DC |
CEC-Listed 240V Equivalents to SMA Solar SC 4000 UP-US 600V 3850A
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (3650.134 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Engineering FAQ — SMA Solar SC 4000 UP-US 600V 3850A
What size circuit breaker does the SMA Solar SC 4000 UP-US 600V 3850A require under NEC 705.12?
At 3650.134 kW continuous AC output on 600V (3512.4A continuous), the 125% continuous duty rule requires a minimum 4400A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the SMA Solar SC 4000 UP-US 600V 3850A?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 3650.134 kW unit with 4015.15 kW to 4927.68 kW DC of solar modules without exceeding 1200V cold Voc.