SMA Solar STP 20-US-50 (20 kW)

20 kW, 480 Vac, 3-phase, transformerless, Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
20 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
350–800V / 800V
NEC 705.12 Breaker
35A @ 480V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
SMA Solar STP 20-US-50 — Real SMA Sunny Boy solar inverter
Real SMA Sunny Boy solar inverterWikimedia Commons — File:Dornbirn-SMA Sunny Boy inverter SWR 3000-01ASD.jpg (CC BY-SA 4.0)
DC INPUT & MPPT TRACKING WINDOW (STRING) MPPT 350–800 Vdc 350V 800V MAX 800V PV DC INPUT ≤ 800V DC 20 kW · 97.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 480V · 35A BRKR

Electrical & Grid-Support Datasheet

SMA Solar STP 20-US-50 Electrical and Grid-Support Specifications
ManufacturerSMA Solar
Model Number (MPN)STP 20-US-50
Inverter TopologyCommercial 3-Phase Inverter
Continuous AC Power (Paco)20 kW (20,000 W)
Nominal DC Input (Pdco)20,397 W
Nominal AC Voltage480 Vac (3-Phase)
CEC Weighted Efficiency97.5%
MPPT Operating Window350 – 800 Vdc (NREL SAM Measured)
Max DC Input Voltage800 Vdc
Max DC Input Current29.6 A
Night Tare Loss4.7 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryUL
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for STP 20-US-50
Max Continuous AC Current24.1 A @ 480V
125% Continuous Duty Current30.1 A
Minimum Standard Breaker35 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (22–27 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for STP 20-US-50
Panel ClassRecommended QtyDC Array / Ratio
400W55–68 panels22.0–27.2 kW DC
440W50–61 panels22.0–26.8 kW DC
550W40–49 panels22.0–26.9 kW DC

CEC-Listed 240V Equivalents to SMA Solar STP 20-US-50

Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (20 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:

CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid

Isuna U20K-PH

CEC Efficiency: 97%
Datasheet →
CEC-Listed · 240V19.378 kW
Base Power · Hybrid

000599.XX.Y

CEC Efficiency: 96%
Datasheet →
CEC-Listed · 240V17.944 kW
SRNE Solar · Hybrid

HEBP48180U380-H

CEC Efficiency: 96.5%
Datasheet →

Compatible Solar Panels for SMA Solar STP 20-US-50

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for SMA Solar STP 20-US-50
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V10–14 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V10–14 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V10–13 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V10–14 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V10–14 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V8–11 per string (-10°C)Verify Pair

Engineering FAQ — SMA Solar STP 20-US-50

What size circuit breaker does the SMA Solar STP 20-US-50 require under NEC 705.12?
At 20 kW continuous AC output on 480V (24.1A continuous), the 125% continuous duty rule requires a minimum 35A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the SMA Solar STP 20-US-50?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 20 kW unit with 22 kW to 27 kW DC of solar modules without exceeding 800V cold Voc.