SMA Solar STPS60US-20 (60 kW)
60 kW, 480 Vac, 3 phase Grid Support Utility Interactive Battery Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
60 kW
CEC Weighted Eff.
98%
MPPT / Max DC
415–980V / 980V
NEC 705.12 Breaker
100A @ 480V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | SMA Solar |
|---|---|
| Model Number (MPN) | STPS60US-20 |
| Inverter Topology | Commercial 3-Phase Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 60 kW (60,000 W) |
| Nominal DC Input (Pdco) | 61,495 W |
| Nominal AC Voltage | 480 Vac (3-Phase) |
| CEC Weighted Efficiency | 98% |
| MPPT Operating Window | 415 – 980 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 980 Vdc |
| Max DC Input Current | 79.3 A |
| Night Tare Loss | 17.33 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | UL |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 72.2 A @ 480V |
|---|---|
| 125% Continuous Duty Current | 90.3 A |
| Minimum Standard Breaker | 100 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (66–81 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 165–203 panels | 66.0–81.2 kW DC |
| 440W | 150–184 panels | 66.0–81.0 kW DC |
| 550W | 120–147 panels | 66.0–80.8 kW DC |
CEC-Listed 240V Equivalents to SMA Solar STPS60US-20
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (60 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Compatible Solar Panels for SMA Solar STPS60US-20
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 11–17 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 11–17 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 11–16 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 12–17 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 12–18 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 9–13 per string (-10°C) | Verify Pair |
Engineering FAQ — SMA Solar STPS60US-20
What size circuit breaker does the SMA Solar STPS60US-20 require under NEC 705.12?
At 60 kW continuous AC output on 480V (72.2A continuous), the 125% continuous duty rule requires a minimum 100A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the SMA Solar STPS60US-20?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 60 kW unit with 66 kW to 81 kW DC of solar modules without exceeding 980V cold Voc.