SMA Solar Sunny Tripower Smart Energy 10.0 (EU) (10 kW)
10 kW, 400V 50Hz Hybrid Inverter (VDE-AR-N 4105 / IEC 62109 (EU 3-Phase)). Registry source: Manufacturer IEC Datasheet (Global Reference) · CEC listing date: · Registry snapshot: .
Continuous AC Output
10 kW
CEC Weighted Eff.
97.4%
MPPT / Max DC
280–800V / 1000V
NEC 705.12 Breaker
20A @ 400V
Inverter Engineering Tools
Global / Non-US Reference: Designed for non-US 50Hz / 230V–400V grids; not UL 1741-SB listed for US interconnection.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | SMA Solar |
|---|---|
| Model Number (MPN) | Sunny Tripower Smart Energy 10.0 (EU) |
| Inverter Topology | Hybrid Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 10 kW (10,000 W) |
| Nominal DC Input (Pdco) | 10,267 W |
| Nominal AC Voltage | 400 Vac (3-Phase) |
| CEC Weighted Efficiency | 97.4% |
| MPPT Operating Window | 280 – 800 Vdc (Manufacturer IEC Datasheet) |
| Max DC Input Voltage | 1000 Vdc |
| Max DC Input Current | 25 A |
| Night Tare Loss | 2 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | VDE-AR-N 4105 / IEC 62109 (EU 3-Phase) |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 14.4 A @ 400V |
|---|---|
| 125% Continuous Duty Current | 18.0 A |
| Minimum Standard Breaker | 20 A |
| Busbar Requirement | 100A Busbar (120% rule: up to 20A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (11–13.5 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 28–34 panels | 11.2–13.6 kW DC |
| 440W | 25–31 panels | 11.0–13.6 kW DC |
| 550W | 20–25 panels | 11.0–13.8 kW DC |
CEC-Listed 240V Equivalents to SMA Solar Sunny Tripower Smart Energy 10.0 (EU)
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (10 kW Hybrid Inverter) and can be added directly to your US System Kit:
Compatible Solar Panels for SMA Solar Sunny Tripower Smart Energy 10.0 (EU)
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 8–17 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 8–17 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 8–17 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 8–18 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 8–18 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 6–14 per string (-10°C) | Verify Pair |
Engineering FAQ — SMA Solar Sunny Tripower Smart Energy 10.0 (EU)
What size circuit breaker does the SMA Solar Sunny Tripower Smart Energy 10.0 (EU) require under NEC 705.12?
At 10 kW continuous AC output on 400V (14.4A continuous), the 125% continuous duty rule requires a minimum 20A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the SMA Solar Sunny Tripower Smart Energy 10.0 (EU)?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 10 kW unit with 11 kW to 13.5 kW DC of solar modules without exceeding 1000V cold Voc.