SolarEdge official logoCEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

SolarEdge NX5000T-US (4.99 kW)

4.99 kW, 240 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
4.99 kW
CEC Weighted Eff.
98.5%
MPPT / Max DC
370–450V / 450V
NEC 705.12 Breaker
30A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
SolarEdge NX5000T-US — Real SolarEdge solar inverter installation
Real SolarEdge solar inverter installationWikimedia Commons — File:SolarEdge-Verdrahtungsbeispiel-01.jpg (CC BY-SA 4.0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 370–450 Vdc 370V 450V MAX 450V PV DC INPUT ≤ 450V DC 4.99 kW · 98.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 30A BRKR

Electrical & Grid-Support Datasheet

SolarEdge NX5000T-US Electrical and Grid-Support Specifications
ManufacturerSolarEdge
Model Number (MPN)NX5000T-US
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)4.99 kW (4,990 W)
Nominal DC Input (Pdco)5,044 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency98.5%
MPPT Operating Window370 – 450 Vdc (NREL SAM Measured)
Max DC Input Voltage450 Vdc
Max DC Input Current12.8 A
Night Tare Loss5.9 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryIntertek
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for NX5000T-US
Max Continuous AC Current20.8 A @ 240V
125% Continuous Duty Current26.0 A
Minimum Standard Breaker30 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (5.49–6.74 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for NX5000T-US
Panel ClassRecommended QtyDC Array / Ratio
400W14–17 panels5.6–6.8 kW DC
440W12–15 panels5.3–6.6 kW DC
550W10–12 panels5.5–6.6 kW DC

Engineering FAQ — SolarEdge NX5000T-US

What size circuit breaker does the SolarEdge NX5000T-US require under NEC 705.12?
At 4.99 kW continuous AC output on 240V (20.8A continuous), the 125% continuous duty rule requires a minimum 30A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the SolarEdge NX5000T-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 4.99 kW unit with 5.49 kW to 6.74 kW DC of solar modules without exceeding 450V cold Voc.

More SolarEdge Inverters

SE3800H-US (3.747 kW)SE3800A-US (3.79 kW)NX3800T-US (3.84 kW)SE5000x (4.99 kW)SE5000H-US (5.052 kW)SE5700H-US (5.7 kW)All SolarEdge Equipment →