SolarEdge official logoCEC-Listed · 240V ResidentialString

SolarEdge SE5000x (4.99 kW)

5 kW, 240 Vac, 1-phase Grid Support Utility Interactive Inverter, where x = (blank), A, or A-US. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
4.99 kW
CEC Weighted Eff.
98%
MPPT / Max DC
370–480V / 480V
NEC 705.12 Breaker
30A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
SolarEdge SE5000x — Real SolarEdge solar inverter installation
Real SolarEdge solar inverter installationWikimedia Commons — File:SolarEdge-Verdrahtungsbeispiel-01.jpg (CC BY-SA 4.0)
DC INPUT & MPPT TRACKING WINDOW (STRING) MPPT 370–480 Vdc 370V 480V MAX 480V PV DC INPUT ≤ 480V DC 4.99 kW · 98% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 30A BRKR

Electrical & Grid-Support Datasheet

SolarEdge SE5000x Electrical and Grid-Support Specifications
ManufacturerSolarEdge
Model Number (MPN)SE5000x
Inverter TopologyString Inverter
Continuous AC Power (Paco)4.99 kW (4,990 W)
Nominal DC Input (Pdco)5,090 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency98%
MPPT Operating Window370 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current12.7 A
Night Tare Loss2.24 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SE5000x
Max Continuous AC Current20.8 A @ 240V
125% Continuous Duty Current26.0 A
Minimum Standard Breaker30 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (5.49–6.74 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SE5000x
Panel ClassRecommended QtyDC Array / Ratio
400W14–17 panels5.6–6.8 kW DC
440W12–15 panels5.3–6.6 kW DC
550W10–12 panels5.5–6.6 kW DC

Engineering FAQ — SolarEdge SE5000x

What size circuit breaker does the SolarEdge SE5000x require under NEC 705.12?
At 4.99 kW continuous AC output on 240V (20.8A continuous), the 125% continuous duty rule requires a minimum 30A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the SolarEdge SE5000x?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 4.99 kW unit with 5.49 kW to 6.74 kW DC of solar modules without exceeding 480V cold Voc.

More SolarEdge Inverters

SE3800A-US (3.79 kW)NX3800T-US (3.84 kW)NX5000T-US (4.99 kW)SE5000H-US (5.052 kW)SE5700H-US (5.7 kW)NX5700T-US (5.76 kW)All SolarEdge Equipment →